Hydrogen  Peroxide  Injection  System  Assembly  &  Installation  Instructions

 

1.

 

Remove  the  Stenner  Econ  FP  pump  and  solution  tank  from  the  box.

 

2.

 

Mount  the  pump  mounting  bracket  to  the  tank  using  customer  supplied  screws.    Be  sure  the  bracket  is  in-­
stalled  so  the  control  panel  is  facing  up.

 

3.

 

Mount  the  pump  to  the  bracket  and  secure  all  screws.

 

4.

 

Drill  a  1/4”  hole  in  the  top  of  the  tank  and  feed  the  supplied  1/4”  line  through  the  hole.    Open  the  cap  and  
reach  in  and  grab  the  tube.  Install  the  weighted  strainer  on  the  tube.    Push  the  tubing  into  the  tank  until  the  
weighted  strainer  is  about  1

-

2”  off  the  bottom  when  the  tube  is  hanging.

 

5.

 

Attach  the  tank  tube  to  the  top  port  on  the  Stenner  pump  using  the  nut  and  farrow  that  was  sent  with  the  
pump.    Install  the  nut  over  the  tubing  then  the  farrow.    The  farrow  has  a  shoulder  side  and  a  tapered  side.    
The  shoulder  side  should  be  installed  on  the  tubing  facing  the  nut.    The  tapered  side  of  the  farrow  will  face  
the  pump.    Install  the  tube  and  tighten  the  nut  hand  tight.

 

6.

 

Shutoff  the  water  supply  and  relieve  the  pressure.    

 

7.

 

Cut  the  pipe  and  install  the  components  as  follows.    The  system  overview  will  provide  the  flow  schematic  for  
installation.    First  install  the  water  meter,  then  install  a  pipe  from  the  water  meter  to  the  injection  tee.  Then  
install  a  pipe  from  the  injection  tee  to  the  inlet  of  the  carbon  filter.    (see  carbon  filter  installation  for  proper  
connection  to  the  carbon  filter)

 

8.

 

Install  a  pipe  from  the  carbon  filter  outlet  to  the  existing  equipment  or  to  the  house  plumbing  if  no  additional  
equipment  is  required.    Be  sure  all  solder  joints  within  18”  of  the  plastic  connections  are  made  prior  to  con-­
necting  to  the  plastic  components.    (see  carbon  filter  installation  for  proper  connection  to  the  carbon  filter)

 

9.

 

Now  install  the  injector  in  the  injection  tee.    Be  sure  to  use  Teflon  tape  to  seal  the  threads  on  the  injector.

 

10.

 

Once  the  injector  is  installed,  turn  the  water  on  and  check  for  leaks.    If  there  are  leaks  fix  them  now.

 

11.

 

Now  install  the  1/4”  tube  from  the  bottom  port  on  the  pump  to  the  injector.    Again,  the  shoulder  side  of  the  
farrow  faces  the  nut  and  the  tapered  side  of  the  farrow  should  face  the  injector  or  pump  connection.

 

12.

 

Once  all  the  tubing  is  connected,  the  water  is  on  and  there  are  no  leaks,  plug  the  pump  into  a  110v  power  
supply.    Now  fill  the  solution  tank  with  peroxide  and  press  and  hold  the  “prime”  button.    Once  the  peroxide  
has  reached  the  injector,  release  the  “prime”  button.

 

13.

 

Now  connect  the  water  meter  wires  to  the  pump  wires.    Red  to  red  and  black  to  black.    An  enclosure  or  wire  
nuts  can  be  used  to  make  this  connection.    These  wires  have  no  voltage  and  do  not  pose  an  electric  shock.    
However,  installing  these  in  an  enclosure  is  the  proper  way  to  connect  them.

 

14.

 

Press  and  hold  the  “mode”  button  then  use  the  “up”  and  ‘”down”  arrows  to  change  the  mode  to  “5  Seconds  
100%”.    Now  press  and  hold  the  “%”  button  and  use  the  “down”  arrows  to  change  the  percentage  to  ‘50%”.    
This  is  a  good  starting  point  for  the  injection  setting.    This  will  be  revisited  later  during  start  up.

 

 
 
 
 

Installation,  Operation  and  Maintenance  Manual

 

Matrixx  Oxi

-

Gen  MO

-

1,  MO

-

2,  MO

-

3,  MO

-

4,  System

 

Summary of Contents for Oxi-Gen 150-MO-1

Page 1: ... Matrixx Oxi Gen Iron Sulfur and Manganese Eradication System Oxi Gen 150 MO 1 Oxi Gen 150 MO 2 Oxi Gen 150 MO 3 Oxi Gen 150 MO 4 US Water Systems Inc 1209 Country Club Road Indianapolis IN 46234 1 800 608 8792 info uswatersystems com www uswatersystems com ...

Page 2: ...6 Carbon Filter Media and Valve Installation 8 Injection System Installation Continued 9 Carbon Filter Installation 10 Carbon Filter Valve Features and Programming 11 System Startup 12 What To Expect and Routine Maintenance 13 Maintenance Schedule 14 System Flow Schematics 15 16 Programming Chart 17 Warranty 18 Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 Syste...

Page 3: ...n number of bathrooms 1 Bathroom 5 GPM 2 Bathrooms 8 GPM 3 Bathrooms 10 GPM 4 Bathrooms 12 GPM 5 Bathrooms 15 GPM Hydrogen peroxide or H2O2 is a powerful yet versatile oxidant that is both safe and effective Consider the H2O2 advantages and you ll know why this is the ONLY sure way to eradicate iron manganese and sulfur Powerful H2O2 is one of the most powerful oxidizers known and is much stronger...

Page 4: ...taminants and the by product is H2O water This is much safer than using chlorine in that chlorine can cause other problems in the water stream such as chloramines and trihalomethanes THM s Once the water has been injected with hydrogen peroxide it passes through the backwashing carbon filter The backwashing carbon filter uses catalytic carbon to act as a catalysis to remove the oxidized contaminan...

Page 5: ... from a dry contact flow switch the pump will run at the selected speed when the switch is closed and stop when the switch opens 24 VAC Input The pump will run at the selected speed when it nreceives a 24 VAC signal from a water softener or other equipment Econ FP is ideal for light duty water conditioning applications Up to 30 gpd 80 psi Wall mountable Adjustable from 10 to 100 Patented quick rel...

Page 6: ... A D pages 12 to 13 Program Pump for SECONDS mode water meter steps 1 4 pages 14 to 15 24 VAC AUXILIARY The pump will accept a 24 VAC signal from a water softener or other type of control equipment that responds to flow and will run at a set speed for as long as it receives the 24 VAC signal The connection is not polarity sensitive polarity is not an issue when connecting the auxiliary wires Instr...

Page 7: ...own arrows are used in conjunction with the button to change MODE the mode of operation The arrows are also used in conjunction with the button to adjust the pump operating time percentage for the 1 5 10 20 OR 60 SECONDS mode water meter or the pump speed setting for the FLOW SWITCH and AUXILIARY operational modes CONTROL PANEL GUIDE INDICATORS The display has four flashing indicators beneath the ...

Page 8: ...ia 5 Use the Funnel provided to pour the media into the tanks Pour it evenly around the hole to ensure it is well distributed in the tank and pour slow enough to keep from plug ging the hole Evenly divide the gravel and carbon and pour in the tanks Important It is a good practice to hold a shop vac close to the funnel to collect any dust that escapes during the filling process Safety glasses and a...

Page 9: ...rbon filter outlet to the existing equipment or to the house plumbing if no additional equipment is required Be sure all solder joints within 18 of the plastic connections are made prior to con necting to the plastic components see carbon filter installation for proper connection to the carbon filter 9 Now install the injector in the injection tee Be sure to use Teflon tape to seal the threads on ...

Page 10: ...for residential drain line should be a minimum of 1 2 Backwash flow rates in excess of 7 gpm or length in excess of 20 re quire 3 4 drain line Commercial drain lines should be the same size as the drain line flow control 4 The inlet on the bypass valve is indicated by an arrow that will point toward the valve The outlet will be indicated by an arrow pointing away from the valve 5 Solder joints nea...

Page 11: ...alue Now press the down arrow to move to the next parameter 6 The next parameter is Regen Days This is the amount of days between backwashes This is factory set to 3 You can use the table on page 4 as a guideline for proper frequency This is only a guideline and ac tual backwash frequency could vary Typically the values on the table will work for 90 of all applications To change this value press a...

Page 12: ...pen the kitchen sink faucet and pull a sample of the water The sample should be full of air bubbles that come to top and dissipate over 1 2 minutes 9 Adjust the pump higher than 50 if necessary until the sample is full of bubbles The pump can be adjusted by holding the button and using the up or down arrows 10 Once there is a sample full of air bubbles from the kitchen sink faucet start to adjust ...

Page 13: ...may be bubbles in the water for a few weeks after installation A few bubbles are fine but if there is fizz that remains for several seconds it is an indication that the system is being overfed with H2O2 This occurs because after installation the water will become cleaner and the initial dosage of H2O2 may need to be adjusted to compensate for the low er contaminant level Routine Maintenance Pressu...

Page 14: ... 5 Years 411 EC30G 2 Injection Panel Duck Bill Check Valve Replace injection check valve as needed 1 5 Years 411 UCCVDBO H2O2 Solution Tank Periodically check the solution level and refill as needed Varies by wa ter usage 710 HP22N Carbon Tank Check the clock and settings periodically or after a power outage 4 Months N A Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 ...

Page 15: ...15 Flow Schematic Single Tank System Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 System ...

Page 16: ...16 Flow Schematic Dual Tank System Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 System ...

Page 17: ...17 Programming Chart Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 System ...

Page 18: ...aused by iron sulfur bacterial iron silt sand tannins or ganics bacteria hot water or chlorine voids the warranty on resin These warranties are in lieu of all other warranties expressed or implied and we do not authorize any person to assume for us any other obligation on the sale of this water conditioner No responsibil ity is assumed for delays or failure to meet these warranties caused by strik...

Page 19: ...ase can be Wghtened by hand as per Figure C or with the opWonal wrench and mulW adaptor as per Figure D Install Tank Base into Tank Thread Figure C Tighten by hand Figure D Op onal ghten by wrench and mul Tadaptor SECTION E 1 Install the clamp ring over the valve threads onto the valve as per Figure E and F Install Clamp Ring onto Valve Thread Figure E Valve threads before clamp ring installed Fig...

Page 20: ...ector SECTION N HTO SoWener Valve Programming Page 2 SECTION H AVach Valve to Tank Base Figure J Insert valve into tank base Figure K Clamp ring installed and ghtened 1T2 turns 1 Insert the valve into the tank base as shown in figure J Insure the o ring is in proper locaWon before inserWng FAILURE TO FOLLOW THIS STEP CAN PINCH AND DAMAGE THE OTRING WHICH MAY RESULT IN A LEAK AND VOID THE PRODUCT WA...

Reviews: