7
System Components
CONTROL PANEL GUIDE –BUTTONS
The control panel has a backlit LCD display;; when operating it will display the operating modes and the % setting.
Following are the six buttons for programming the modes of operation.
Scrolls through the available modes of operation: 1 SECOND, 5 SECONDS, 10 SECONDS, 20
SECONDS, 60 SECONDS (water meter), FLOW SWITCH or AUXILIARY.
Adjusts the pump operating time percentage for the 1, 5, 10, 20, or 60 SECONDS mode (water meter)
or adjusts the pump speed in the FLOW SWITCH and AUXILIARY modes.
Operates the pump at full speed when the button is pressed.
Places the pump in standby. The pump will not respond to incoming signals when in standby.
The up and down arrows are used in conjunction with the
button to change
MODE
the mode of operation. The arrows are also used in conjunction with the
button to adjust the
pump operating time percentage for the 1,5, 10, 20 OR 60 SECONDS
mode (water meter)
or the pump speed setting for the FLOW SWITCH and AUXILIARY operational modes.
CONTROL PANEL GUIDE –INDICATORS
The display has four flashing indicators beneath the operating mode and setting. The
indicators are “PRIME”, “STANDBY”, “SIGNAL”, and “PAUSE” and represent the
following functions:
PRIME =
Prime button is pressed, pump will run full speed
STANDBY =
Standby button was pressed, pump is in standby
SIGNAL =
Pump received a signal
PAUSE =
Pump received a dry contact to the pause input
Installation, Operation and Maintenance Manual
Matrixx Oxi
-
Gen MO
-
1, MO
-
2, MO
-
3, MO
-
4, System
MODE
%
PRIME
STBY
MODE
%
Operating Mode
Percentage Setting
Flashing Indicators
Control Panel