![US Robotics USR4204 User Manual Download Page 23](http://html1.mh-extra.com/html/us-robotics/usr4204/usr4204_user-manual_1063618023.webp)
USR4204 User Guide
Page
23
of
52
Configure Parameters Menu (Main Menu
Y)
At the top of the Configure Parameters Menu is a banner that displays the current system
parameters. Directly below the banner are the menu name, the user-programmable device
name, the firmware version number and date, and the serial number of the USR4204. Below
that is a list of valid commands and text. Invalid commands are ignored.
'T' Change Inactivity Timeout
The USR4204 will close a serial port if no data passes in or out of the terminal or serial port
before this inactivity time lapses. If security is enabled, the session will also logout.
Valid range: 0 to 255 minutes (0 disables the timer)
Default: 005
'R' Rename
Rename the USR4204 with this command. It navigates to the Rename screen. The USR4204
name may be up to 32 (displayable) characters in length.
Default: USR4204
'S' Change Char for Escape
Change the Escape Sequence character with this command. It navigates to the Change
Character screen.
The Escape Sequence may be disabled by programming this character to a control-\. To
enter control-\ in the Change Character screen, hold down the Ctrl key and press \
T/O Esc Menu Xon Xoff Flow Pass Echo AutoCR DCD Banr
005 - - ^Q ^S OFF OFF ON ON OFF OFF
----------------------------------------------------
Configure Parameters Menu Ver 1.12 09/18/13 S/N: 1ME4Z7PM0004
CMD CMD
'T' Change Inactivity Timeout 'R' Rename System
'S' Change Char for Escape 'M' Change Char for Menu
'N' Change Char for Xon 'X' Change Char for Xoff
'W' Enter Login Banner 'Y' Enter Security Banner
'F' Toggle S/W Flow Control 'P' Toggle Xon/Xoff Pass Thru
'E' Toggle Command Echo 'A' Toggle Auto CR
'D' Toggle DCD Override 'B' Toggle Security Banner
'U' Config Security '&' Load Factory Parameters
'-' Return to MAIN Menu '!' Flash New Code