Symptom
Cause
Action
Engine is gutless or
runs unevenly
Air filter
Fuel system
(Blue exhaust)
(Voluminous blue
white exhaust)
(Black exhaust)
Ignition system
Clogged air filter.
Machine stored without observing
proper procedure from chapter
“Storage/Winter storage”.
Tank filled with 2cycle mixed oil.
Tank filled with diesel.
Choke left on.
Clogged air filter.
Carburetor problems.
Wrong spark plug type.
Buildup on electrodes.
Short circuit.
Faulty ignition unit.
Clean or replace the air filter.
Clean tank, sludge reservoir and
empty carburetor.
Fill the tank with proper fuel.
Fill the tank with proper fuel.
Clean tank, sludge reservoir and
empty carburetor.
Fill the tank with proper fuel.
Open choke valve.
Clean or replace the air filter.
Contact an authorized service
workshop.
Replace the spark plug.
Check electrode gap and clean
or replace spark plug.
Contact an authorized service
workshop.