Document Title:
MTP
®
Loopback Casing Installation
Document Number: AEN-1430, Rev. 1.0
12 of 17 THE USE OF SAFETY GLASSES FOR EYE PROTECTION IS RECOMMENDED
4.4
The remaining steps apply to both one-row and two-row loopback assemblies.
Carefully slide the spring and ferrule boot onto the ribbon. Refer to the
appropriate MTP termination AEN listed in Table 4.1 to determine the correct
orientation of the ferrule boot relative to the ferrule.
Figure 4.4
4.5
Follow the steps in the appropriate MTP termination AEN listed in Table 4.1 to
terminate and polish the ferrule and install the connector hardware. The complete
MTP connector will look similar to Figure 4.5-3.
Figure 4.5-1
Figure 4.5-2
Figure 4.5-3