Document Title:
MTP
®
Loopback Casing Installation
Document Number: AEN-1430, Rev. 1.0
13 of 17 THE USE OF SAFETY GLASSES FOR EYE PROTECTION IS RECOMMENDED
5.0
Loopback Casing Installation
5.1
Install the MTP connector in the non-handle half of the casing as shown. The
connector can be installed with the key up or key down. Ensure that the lip on the
connector outer housing is in the window of the casing and at the very edge of the
window (Figure 5.1-2); otherwise, the casing may not close properly in Step 5.2.
Figure 5.1-1
Figure 5.1-2
Note:
Ensure the fibers do not extended beyond the covered section of the non-
handle half of the casing.
Figure 5.1-3 Figure 5.1-4
5.2
Install the handle half of the casing by interlocking the hooks with the non-handle
half first (Figure 5.2-1) then carefully snapping the two halves together. Ensure all
four side latches are fully engaged (Figure 5.2-2).
Figure 5.2-1 Figure 5.2-2