Meter are Average responding and calibrated
to the RMS value of a sine wave input.
Function
Volts DC
Range
Resolution
Accuracy
20 V
200 V
600 V
10 mV
100 mV
1 V
±1.5 %+3 dgts
Overload protection
600 V
Function
Volts AC
(45Hz to 450 Hz)
Range
Resolution
Accuracy
200 V
600 V
100 mV
1 V
±1.5 %+5 dgts
Overload protection
600 V
Function
Ohms
Range
Resolution
Accuracy
200 Ω
0.1 Ω
±1.5 %+5 dgts
Overload protection
600 V
Function
Continuity
Range
Resolution
Accuracy
OPEN CIRCUIT TEST VOLTAGE: 3 V
THRESHOLD: Approx. <50 Ω
Overload protection
600 V
6. ESPECIFICACIONES GENERALES
Maximum Voltage between any terminal
and earth:
600 V
Digital Display:
3 ½ digits, 2000 counts with
automatic polarity indication
Reading Time:
2-3 readings per second
Input Impedance:
10M ohm
Storage Temperature:
-10 °C to 50 °C (14 °F
to 122 °F)
Operating Temperature:
0 °C to 40 °C (32 °F
to 104 °F)
Altitude:
2 000 m (6 562 feet)
Relative humidity:
0% to 80% (0 °C to 35 °C)
- 0% to 70% (35 °C to 45 °C)
Pollution Degree:
2
Installation Category:
III
Battery Type:
9V, NEDA 1604 or IEC 6LR61
Battery Life:
200 hrs. typical (alkaline)
Size (H x W x L):
Without Holster 36 x 70 x 140
mm With Holster 54 x 80 x 154 mm
Weight:
Without Holster: 220g (7.7 oz)
With
Holster : 380g (13.4 oz)
Accessories Supplied:
Test leads set, 9 V
battery, Protective Holster and Instruction Sheet