4
−−−−
sec.3h
2 VOICE - Technical Manual
CALL MODULE
DIGITAL CALL MODULE Ref.1083/19 (2 Modules)
PROGRAMMING
A connector is provided for connecting the Ref. 1748/40 (colour),
camera module to the back of the calling module:
RED
– Positive power supply (+TC)
BLACK
- Negative power supply (R1)
WHITE
- Video signal coax (V3, V5)
Ref.
1083/19
Ref.
1748/40
(default)
V3 - V5
System with coaxial cable
Camera
Leds On
Camera
Leds Off
PRODUCT LIST
Sinthesi range products and accessories can be used to install the
call module. The main codes which can be used are listed below.
FLUSH MOUNTING BOXES
For 2 modules
Ref. 1145/52
For 3 modules
Ref. 1145/53
For 4 modules
Ref. 1145/54
RAIN HOODS
For 2 modules
Ref. 1158/612
For 3 modules
Ref. 1158/613
For 4 modules
Ref. 1158/614
For 4 modules (2 module holders with 2 modules)
Ref. 1158/624
HOODED HOUSINGS
For 2 modules
Ref. 1148/312
For 3 modules
Ref. 1148/313
For 4 modules
Ref. 1148/314
For 4 modules (2 module holders with 2 modules)
Ref. 1148/324
BLANK MODULE AND REPERTORY
Repertory modules
Ref. 1158/50
Blank modules
Ref. 1158/59
PROGRAMMING
Enter the code 99999 to access the con
fi
guration and programming
menu; the display shows:
PASSWORD
_
Enter the password (default 1000) and press
to access the
following programming menu:
LANGUAGE
CONFIGURATION
NAMES
DOOR OPENER
Select the operating language and
con
fi
rm with
See “con
fi
guration programming”
See “name programming”
See “programming of door-opener
codes”
Use the arrow keys to scroll the programming menu. Press
to access the selected second level menu; press
X
to quit
programming.
In the language menu, select the operating language and con
fi
rm with
.
CONFIGURATION PROGRAMMING
The con
fi
guration menu is as follows:
CONFIGURATION
MODULE TYPE
<PRI> <SEC>
MODULE ID
00
CODE TYPE
<PHYS> <LOGIC>
DEVICE TYPE
<AUDIO> <VIDEO>
BUSY TIME
30
STOPABLE
<YES> <NO>
DOOR LOCK T1
01
DOOR OPENER 1
<FREE> <SECRET>
DOOR LOCK T2
01
DOOR OPENER 2
<FREE> <SECRET>
PASSWORD
1000
CONTROL CAMERAS
<0> <1> <2> <3> <4>
LCD CONTRAST
<+> <->
BUTTON SOUND
<YES> <NO>
DAY
<MONDAY>
TIME
12:30
POSTMAN FUNCTION
<YES> <NO>
X
MONDAY
<YES> <NO>
If YES
If the value entered is not
correct, the display shows
...
SECONDARY
<0> <1>
Exit programming
Only if secondary
FROM 00:00
TO 00:00
CODE NOT
ALLOWED
SUNDAY
<YES> <NO>
FROM 00:00
TO 00:00
CONFIGURATION PARAMETER
To access the con
fi
guration menu, enter the code 99999 followed by
the password (default 1000) and the
key. Then, press the
key
and press
.
Press
to con
fi
rm selection; press
X
to cancel selection. Pressing
X
for 3s returns to the start of the menu; to quit, press
X
again.
Module type
The calling module may be a main or secondary device. All systems
users can be called from the main device; only users of the related
riser column can be called from the secondary device. The user who
receives the call is able to distinguish the origin of the call according
to ring duration.
There may be 2 secondary call stations with different numbers in the
same riser column (secondary 0 or 1).
Module ID: door unit number
Set a number from 00 to 03 for a main module or from 00 to 31 for a
•
•
Ref. 1083/19
DIGITAL CALL MODULE