background image

sec.3h 

−−−−

 

5

2 VOICE - Technical Manual

CALL MODULE

DIGITAL CALL MODULE Ref.1083/19 (2 Modules)

PROGRAMMING

secondary module.

Two main stations cannot have the same ID. Two secondary 

stations may have the same ID but must have a different number 

(see next parameter).

The ID of the secondary door unit must be the same as the riser 

column ID set in the Ref. 1083/50 riser column interface.

Secondary

In the case of a secondary module and if there is only one secondary 

in the riser column, set 0; if there are 2, set 0 and 1 in the two 

secondaries.

Code type 

Type of user call code.

Physical code: users are called with a 5-digit code as follows: 

ccnnn, where cc indicates the riser column (from 00 a 31) and 

nnn indicates the number of the apartment (from 000 a 127)

Logical code: users are called with a a number of 1 to 4 digits 

from 1 to 9999. To use the logical codes, the names must be 

programmed, assigning the logical call code to the physical code 

of the apartment.

Device type 

Indicates whether the module is equipped with local camera unit.

Video: a local camera is connected to the “VIDEO MODULE” 

connector; the call station is a video door phone. Up to 4 

surveillance cameras, which can be displayed by users using the 

auto power-on key, can be connected to the  V3/V5 input.

Audio: no local camera unit is connected to the “VIDEO MODULE” 

connector; the call station is a door phone. Up to 4 surveillance 

cameras, which can be displayed by users using the auto power-

on key, can be connected to the V3/V5 input. In the case of a 

single  surveillance camera, the call station becomes a video 

door phone and uses this camera in the call phase.

Busy time

This is the guaranteed communication time. The values (in seconds), 

which can be selected with the arrow keys, are 01, 10, 20, …, 70.

The guaranteed communication time must be programmed in 

the same way for all system call stations.

Stopable

During auto power-on or an intercommunicating call or consultation of 

the video door phone answering service, the riser column concerned 

or the entire system is in Busy status which, according to how this 

parameter is programmed, may or may not be interrupted by a call 

from the door unit.

The parameter “interruption” must be programmed in the same 

way for all system call stations.

Door lock T1

Maintenance time of the main entrance electric lock (terminals SE+/

SE-) and of activation of terminals C/NC/NO.  Enter a number (in 

seconds) from 1 to 90.

Door opener 1

Electric lock control may be “protected by privacy feature” or 

“unrestricted”.  The door unit behaves as follows in the two cases:

Secret (Private): pressing the door-opener button of an apartment 

station, the electric lock of the call station is released only if a call 

has been received or a voice conversation is in progress with 

this or if, following auto power-on,  it is in video connection with 

this.

Free (Unrestricted): pressing the door-opener button of an 

apartment station, the electric lock of the door unit is released 

only if this has been con

fi

 gured as main, or the user belongs 

to the riser column of the same secondary door unit. This riser 

column is de

fi

 ned by the ID of the secondary door unit. This 

function is normally used on secondary stations.

Door lock T2

Activation time of the vehicle entrance electric lock (SE2 terminals).  

Enter a number (in seconds) from 1 to 90.

§

§

Door opener 2

The electric lock may be controlled in “private” or “unrestricted” 

mode.  The door unit behaves as follows in the two cases:

Secret (Private): pressing the door-opener button of an apartment 

station, the electric lock of the call station is released only if a call 

has been received or a voice conversation is in progress with 

this or if, following auto power-on,  it is in video connection with 

this.

Free (Unrestricted): pressing the door-opener button of an 

apartment station, the electric lock of the door unit is released 

only if the door unit is con

fi

 gured as main, or the user belongs 

to the riser column of the same secondary door unit. This riser 

column is de

fi

 ned by the ID of the secondary door unit. This 

function is normally used on secondary stations.

Password

Password for accessing con

fi

 guration and programming of call 

module data.

Set a value from 1000 to 9999 (default 1000).

Control cameras

Number of surveillance cameras connected to terminals V3/V5 (if 

more than one, via the 1083/69 video switch).

LCD contrast

Press the UP key to increase contrast and the DOWN key to reduce 

this.

Button sound

The button sound function can be disabled.

Day

With the arrow keys, select the day of the week to be programmed in 

the internal calendar.

Time

Enter the time to be programmed on the internal clock.

Postman function

If the function is enabled, the main entrance can be opened simply by 

pressing the 

 key on the days and at the time set in the following 

screen pages. The function can be enabled for each day of the week, 

also de

fi

 ning the related time band.

 

On exiting con

fi

 guration, a check is made on whether the system 

already comprises a device of the same type with the same ID and, if 

secondary, with the same number (0 or 1). If so, the following message 

is displayed:

ERROR ID

In this case, return to con

fi

 guration and correct the error.

DIGITAL CALL MODULE

Ref. 1083/19

Summary of Contents for 1083/19

Page 1: ...ming 4 Configuration parameter 4 Name programming 6 Programming of door opener code 6 Audio adjusting 6 Call to users 7 Call by entering physical code 7 Call by entering logical code 7 Call by selecti...

Page 2: ...t feature Postman function direct opening of main entrance with key on days and at times programmed Direct call to switchboard if two buttons are pressed at the same time Management of main entrance H...

Page 3: ...ecret Vehicle entrance door opener time 1s Type of vehicle entrance door opener secret Password 1000 Number of surveillance cameras 0 Key click Yes Postman function no To restore the default values po...

Page 4: ...Use the arrow keys to scroll the programming menu Press to access the selected second level menu press X to quit programming In the language menu select the operating language and confirm with CONFIG...

Page 5: ...tricted The door unit behaves as follows in the two cases Secret Private pressing the door opener button of an apartment station the electric lock of the call station is released only if a call has be...

Page 6: ...de is not to be assigned to the user inserted press If a door opener code to be assigned to the user inserted enter the door opener code which must be a 4 digit number from 0001 to 4999 This code will...

Page 7: ...e system is free the call is made and for the entire pick up wait time max 60s the display shows CALLING If the system is busy the display shows LINE BUSY WAIT When the system is free again the call c...

Page 8: ...the call module the door pedestrian or vehicle can be opened entering this code The main entrance lock is activated for codes from 0001 to 4999 the vehicle entrance lock is activated for codes from 5...

Page 9: ...systems TERMINAL PINS DESCRIPTION V3 Video signal for system with coaxial cable modules V5 Video signal ground for system with coaxial cable R1 Camera power supply negative TC Camera power supply pos...

Page 10: ...LLATION CAMERA MODULE Ref 1748 40 6 If required replace the cross slotted screws with security screws provided with the camera 5 Adjust the camera orientation A B A B Position the frame on the module...

Page 11: ...g field REPERTORY MODULE Ref 1148 50 Repertory modules are normally used to indicate the house number or contain other information Power terminals 0 and 12 to light the unit via LEDs The procedure for...

Page 12: ...12 sec 3h 2 VOICE Technical Manual CALL MODULE...

Reviews: