sec.3h
−−−−
3
2 VOICE - Technical Manual
CALL MODULE
DIGITAL CALL MODULE Ref.1083/19 (2 Modules)
TECHNICAL CHARACTERISTICS - DEFAULT CONFIGURATION - INSTALLATION
DIGITAL CALL MODULE
Ref. 1083/19
Power voltage (LINE): ........................................................
36 – 48 Vdc
Power voltage (+ -): ...........................................................
36 – 48 Vdc
Stand-by consumption: .....................................................
Max 85 mA
Max. consumption (Video call): ................................................
220 mA
Lock output SE+ e SE-: .............
capacitance discharge 22 – 24 Vdc
+ holding current max 200 mA
Lock relay C/NC/NO:......................................................
Max 24 V 5 A
Lock relay SE2: .......................................................
Max 24 V 300 mA
Working temperature range:........................................
10 °C ÷ + 50 °C
ILA: ..................
speech output for hearing-impaired European law
SOCU0611477A
DEFAULT CONFIGURATION
Function
Default
Language:
italian
Module type:
main
Module ID:
0
Code type:
physical code
Device type:
video
Busy time:
30s
Interruption:
not enabled
Main entrance lock time:
1s
Type of main entrance door-opener:
secret
Vehicle entrance door-opener time:
1s
Type of vehicle entrance door opener:
secret
Password:
1000
Number of surveillance cameras:
0
Key click:
Yes
Postman function:
no
To restore the default values, power the device holding down the X,
8 and 6 keys.
INSTALLATION
Install the module at the height shown
Fit the module holder frame in the
fl
ush-mounting box
Fit the modules in the frame
Tip the frame and connect wires
Close the frame
Fit the panel on the frame
h = 1,55 ÷ 1,60 m (*)
1
X
7
4
3
9
6
2
0
8
5
(*)
For disabled or special needs users of the D1 type (elderly) and D2
type (lower limb motor dif
fi
culties), the centre of the device must be
arranged at a height comprised between 75 cm and 140 cm with
respect to the
fl
oor. For more details, see technical standard CEI
64-21:2016-12 – Residential environments. Systems suited for use
by people with disabilities or special needs.
Position the panel on the frame
Fasten the screws B on screws A.
•
•
•
•
•
•
•
•
4 mm
A
A
B
A
B
A
A
B
CAMERA MODULE CONNECTION