ACCESSORIES
sec.4c
−−−−
9
2GO! - Technical manual
VIDEO MEMORY MODULE Ref. 1082/88
SEGRETERIA
VIDEOCITOFONICA
Sch./Ref.
1082/88
180 mm
(10 DIN modules)
90 mm
55 mm
The Ref. 1082/88 video door phone answering machine (SVC for
short) is designed for 2GO! systems for storing
fi
lms of unanswered
calls recorded by a video door phone station.
In brief, the functions of the SVC include:
Centralised function: up to eight 7-second
fi
lms can be stored for
each user (up to 32) in the system.
Users can play and delete the
fi
lms by pressing the rhomboid
button on the video door phone.
Films can be sent as MMS messages by a Ref. 1082/52 GPRS
modem. This function is available for the one-family 2GO! kits only
and can be activated and deactivated by appropriately connecting
two dedicated terminals.
Date, time, and other diagnostic messages appear on a four-digit
display.
Three buttons for adjusting date and time and using other test
functions.
SEGRETERIA
VIDEOCITOFONICA
Sch./
Ref
.
1082/88
Display
Function
buttons
Transformer
(provided)
Serial
modem port
Line terminal
Led
3
2
1
4
7
6
5
8
TECHNICAL SPECIFICATIONS
Terminal power (0~, 12~):
13Vac ÷ 21Vac
15Vdc ÷ 28Vdc
Maximum terminal draw (0~, 12~):
350mAdc
Temperature:
-5°C / +45°C
Memory capacity:
8
fi
lms per user
7 seconds per
fi
lm
user
manager
This is a class A device. The device can cause radio interference
in residential environments. The installer may need to take
appropriate measures in such a case.
•
•
•
•
•
§
INSTALLATION
For the installation are valid the generic rules of the 2GO! system.
Observe the following rules:
1. Maximum number of devices
: Only one SVC can be installed
in a 2GO! system. This device is included in the TOTAL count of
2GO! devices. Possible system con
fi
gurations:
3 door units, 1 SVC, 31 apartment stations, 31 distributors.
2 door units, 1 SVC, 32 apartment stations, 31 distributors.
2. Type of usable wires.
The same distances for Atlantico video
door phone apartment stations using the same types of wire apply
for connecting the SVC to the system (LINE terminals). Refer to
the section 2.
3. Wiring and line terminals.
The SVC can be connected in in-
out mode (Z terminal = OFF), via distributor (Z terminal = ON) or
directly to a power line (Z terminal = ON).
1
2
3
4
LINE4
LINE3
LINE2
LINE1
LINE0
Terminal
ON
Terminal
ON
Terminal
ON
3
2
1
4
7
6
5
8
TC
Terminal
OFF
Terminal
ON
1
2
3
4
LINE4
LINE3
LINE2
LINE1
LINE0
Terminal
ON
3
2
1
4
7
6
5
8
TC
1
2
3
4
LINE4
LINE3
LINE2
LINE1
LINE0
(IN/OUT
)
LINE
(DER)LINE
ON
OFF
1082/51
PAT
ENTED
Terminal
ON
Terminal
ON
Terminal
ON
3
2
1
4
7
6
5
8
TC
Line terminal
ON
OFF
Z
4. Installation.
The SVC can be installed in an electrical panel
on a DIN bar (it occupies ten 18mm DIN m two 18mm
DIN modules for the power transformer). Terminal boards and
con
fi
guration dip switches are accessible with the electrical panel
open.
•
•
VIDEO MEMORY MODULE REF. 1082/88
TECHNICAL SPECIFICATIONS
INSTALLATION
VIDEO MEMORY MODULE
Ref. 1082/88