urmet domus 1072/59 Technical Manual Download Page 11

ACCESSORIES

sec.4c 

−−−−

 

11

2GO! - Technical manual 

GPRS MODEM Ref. 1082/52

The SVC can be enabled to send the recorded 

fi

 lm as MMS messages 

in one-family 2GO! systems. The Ref. 1082/52 GPRS modem if 

required for this function.

To enable MMS transmission, leave the MMS terminals on the SVC 

open. If this is not so (MMS terminals reciprocally closed), the SVC will 

work normally but no MMS messages will be sent.

The GPRS modem Ref. 1082/52 may be used also for remote 

programming of the calling modules. For further information, see the 

paragraph on interface Ref. 1082/53.

PROGRAMMING THE MMS MESSAGING 

PARAMETERS

A number of parameters must be programmed via SMS text messages 

sent to the SIM card in the GPRS modem connected to the SVC for 

correct MMS messaging using the external GPRS modem. 

The following parameters must be programmed:

Access password for the programming SMS text messages.

Telephone number where to send recorded 

fi

 lm MMS messages 

(TEL1).

Modem connection parameters to the cell phone network.

MMS Messaging activation.

The following optional commands can be sent:

Program additional MMS messaging telephone numbers.

Delete MMS messaging numbers.

View MMS messaging numbers.

Deactivate MMS messaging function (only if this function is 

physically enabled by leaving the MMS terminals open).

Reactivate MMS messaging function (only if this function is 

physically enabled by leaving the MMS terminals open).

All parameters are programmed by receiving appropriately formatted 

SMS text messages. All commands and parameters can be written 

either in upper or lower case.

For the optional programming refer to the instruction supplied 

with the SVC.

§

PROGRAMMING THE ACCESS PASSWORD 

AND MMS MESSAGING NUMBER (TEL1)

Proceed as follows to program the password and the 

fi

 rst telephone 

number where to send the MMS messages:

1.   Press 

 and   at the same time. The SVC will switch to 

programming mode and the following message will appear on the 

display:

P r o

At this point the SVC will stand by for up to 10 seconds to receive the 

password programming SMS and TEL1. 

2.   Send the following SMS to the SIM card modem connected to the 

SVC:

 svc 

psw=abcdef

 where:

‘abcdef’ is the password (6 letters or digits).

The TEL1 telephone number is automatically acquired from the 

SMS message caller’s ID

3.   The SVC will send the following replay to con

fi

 rm programming:

 

svc tel1

=OK

4.   Press the button    to quit programming. At this point, all the 

other programming parameters can be sent at any time without 

the SVC being in programming mode providing they contain 

the programmed password ‘abcdef’ and are sent from enabled 

telephones (TEL1 or other telephones enabled later).

PROGRAMMING THE MODEM CONNECTION 

PARAMETERS FOR CONNECTING TO THE 

CELL PHONE NETWORK

1.  Send the following SMS text message to the modem after 

programming the password:

 

1.1 TIM SIM card procedure

 

 

svc  

abcdef  

MMS=CFG   GAP=mms.tim.it  

PSR=213.230.130.89

  MUL=http://mms.tim.it/servlets/mms 

PRT=80

 

1.2  Vodafone SIM card procedure

 

 

svc  

abcdef  

MMS=CFG   GAP=mms.vodafone.it 

PSR=10.128.224.10

  MUL=http://mms.vodafone.it/servlets/mms 

PRT=80

 

1.3  Wind SIM card procedure

 

 

svc  

abcdef  

MMS=CFG   GAP=mms.wind.it  

PSR=212.245.244.011

  MUL=http://mms.wind.it 

PRT=8080

The various parameters are subject to changes. For example, 

Wind provides two different con

fi

 gurations only one of which is 

working and current.

 

It is advisable for this reason to check validity of the procedures 

by calling the telephone company’s Call Centre before entering 

the SVC parameters.

2.  The SVC will send the following replay to con

fi

 rm programming:

 

svc MMS=CFG OK

MMS MESSAGING ACTIVATION

1.   To activate MMS messaging, send the SMS text message to the 

modem connected to the answering machine:

 

“svc paswrd MMS=OK”

 

where paswrd is the password stored during the programming 

procedure.

2.   The SVC will reply by sending a SMS text message:

 

“svc MMS=OK”

§

GPRS MODEM Ref. 1082/52

PROGRAMMING

MMS MESSAGING ACTIVATION

GPRS MODEM

Ref. 1082/52

Summary of Contents for 1072/59

Page 1: ...ON 10 Recording films 10 Film playback 10 Download from www urmetdomus com Technical Manuals area SECTION CONTENTS Some products may be described in the New section GPRS MODEM Ref 1082 52 11 PROGRAMMING THE MMS MESSAGING PARAMETERS 11 PROGRAMMING THE ACCESS PASSWORD AND MMS MESSAGING NUMBER TEL1 11 PROGRAMMING THE MODEM CONNECTION PARAMETERS FOR CONNECTING TO THE CELL PHONE NETWORK 11 MMS Messagin...

Page 2: ... load activation relay contact common LINE Non polarised bus line LINE PC Remote button connection terminals PC SPECIAL DECODING Ref 1082 80 O N P E NA IN F S U P C O D M T P R O G T IM E R O F F M O N T O N O N 1 2 3 Sch 1082 80 NC C Z PC LINE 61 mm 108 mm 6 DIN modules 90 mm The Ref 1082 80 special decoder is used in 2GO systems to operate electrical loads thanks to a relay with 230Vca 5A contac...

Page 3: ... M T PROG TIMER OFF M ON T ON ON Sch 1082 80 NC C Z PC LINE ON 3 2 1 Arrange the COD dip switch in the on position ON DIP 4 3 2 1 5 ON 3 2 1 ON 2 1 ON DIP 4 3 2 1 5 ON PE NA INF SUP COD M T PROG TIMER OFF M ON T ON ON Sch 1082 80 NC C Z PC LINE ON 1 2 At this point assign a user code from 0 to 31 to the special decoder To do this set the INF and SUP dip switches to the same value as the user code ...

Page 4: ...atively by one of the following 3 events 1 Pressure of the door opening button on an apartment station 2 Pressure of the switchboard calling button on an apartment station 3 Pressure of the staircase light button on an apartment station and or door unit 1 Operation following pressure of the door opening button on an apartment station This service can be activated by pressing on an apartment statio...

Page 5: ...m 0 to 8 can switch the special decoder relay while this function is not allowed to users with code 9 The last operation is self learning of the switchboard call button pressure event Press the special decoder programming button The LED will start blinking ON DIP 4 3 2 1 5 ON 3 2 1 ON 2 1 ON DIP 4 3 2 1 5 ON PE NA INF SUP COD M T PROG TIMER OFF M ON T ON ON Sch 1082 80 NC C Z PC LINE Go to any use...

Page 6: ...se light button of door units with ID 1 and 3 it cannot be activated from door unit with ID 2 At this point program a staircase light function for each door unit which must activate the special decoder 1 Set the dip switch ID to 0 to start programming the door unit The door unit will beep every five seconds to indicate that programming is in progress and the yellow LED will be on ID 1 2 ON 2 Hold ...

Page 7: ...r must be INF SUP Program the user group for activating the special decoder must be INF SUP Program the user group for activating the special decoder must be INF SUP 1 2 3 4 5 INF 1 2 3 4 5 SUP 1 ON OFF OFF OFF COD OFF ON 2 OFF ON OFF ON OFF ON OFF ON M T TIMER Other programming Program the intercom code on an apartment station button for activating the special decoder The apartment stations are a...

Page 8: ... device away from sources of heat and in a place protected from humidity and water sprays Be very careful when handling printed circuit components and particularly the metallic antenna during installation and programming The metallic antenna must not be moved from its original position Before final installation of the device make a test call to check that the radio signal is correctly picked up by...

Page 9: ...l environments The installer may need to take appropriate measures in such a case INSTALLATION For the installation are valid the generic rules of the 2GO system Observe the following rules 1 Maximum number of devices Only one SVC can be installed in a 2GO system This device is included in the TOTAL count of 2GO devices Possible system configurations 3 door units 1 SVC 31 apartment stations 31 dis...

Page 10: ...door phone lights up and the following image appears This means that there are no stored films The video door phone will go out after a few seconds Case C If the line is not busy and there are stored films the video door phone will light up and the number of stored films will appear 3 The number of films will appear for two seconds and then the first stored film will be played 15 05 04 10 27 1 3 7...

Page 11: ...itch to programming mode and the following message will appear on the display P r o At this point the SVC will stand by for up to 10 seconds to receive the password programming SMS and TEL1 2 Send the following SMS to the SIM card modem connected to the SVC svc psw abcdef where abcdef is the password 6 letters or digits The TEL1 telephone number is automatically acquired from the SMS message calle...

Page 12: ...th traditional 4 N audio and coaxial cable It is also possible to use the interface to connect a 2GO Column to a Ref 788 51 relay box connected to a traditional 4 N one family video door phone kit This way you can use a secondary calling station and a traditional apartment station SPECIFICATION The apartment station PABX or coax video door phone or 4 N door phone connected to the interface provide...

Page 13: ...t be identified with a univocal code Set the dip switches as shown below to do this USER CODE Set the code from 0 to 31 by arranging the CODE dip switches as shown in the following table USER 6 4 3 2 1 5 USER 5 4 3 2 1 5 USER 4 4 3 2 1 5 USER 7 4 3 2 1 5 USER 10 4 3 2 1 5 USER 9 4 3 2 1 5 USER 8 4 3 2 1 5 USER 11 4 3 2 1 5 USER 14 4 3 2 1 5 USER 13 4 3 2 1 5 USER 12 4 3 2 1 5 USER 15 4 3 2 1 5 USE...

Page 14: ...14 sec 4c 2GO Technical manual ...