DS1067-056D 

 

CONNECTING THE TELEPHONE LINE 

If you want to connect the unit to the PSTN telephone line use one of these diagrams: 
 

 

 
The control panel must be the first device connected to the incoming telephone line (all the other potential 
devices - fax, answering machine, and telephones - must be downstream from the control panel). This type 
of  connection  guarantees  that,  if  needed,  the  control  panel  can  always  engage  the  telephone  line, 
excluding all the other devices connected if necessary.

 

 

Handle the twin telephone line carefully, as it may be live from the telephone control panel power supply. 
When connecting the twin telephone line to the LA and LB terminals of the interface, it is not necessary to 
take polarity into account. 
The 1067/002A board has a yellow LED to indicate if the telephone line is engaged. 

 

The telephone interface must be grounded The telephone interface is already equipped with one protection 
that is appropriate to the regular needs as required by the existing regulations.  

 

If there should be high risk of electrical shock on the telephone line in the work area, it is advisable to install 
supplementary protection (not provided) on upstream of the control panel on the telephone line. 
 

TECHNICAL SPECIFICATIONS

 

Nominal power voltage ................................................................................................................... 13.8 Vdc 
(taken from the control panel) 
Nominal current absorbed at 12 Vdc 
in stand-by ............................................................................................................................................ 3 mA 
in telephone line connection ............................................................................................................... 20 mA 
Reference standard .................................................................................................................... EN50136-2 
ATS Classification ................................................................................................................................. SP2 
Operating mode ...................................................................................................................... Pass-Through 
 

Summary of Contents for 1067 Series

Page 1: ...DS1067 056D LBT8995 COMUNICATORE PSTN PSTN COMMUNICATOR TELEFON KOMMUNIKATOR PSTN Sch Ref Typ 1067 002A Mod 1067 ...

Page 2: ...ZIONE In questo documento sono riportate solo alcune indicazioni essenziali sul prodotto Per ulteriori e dettagliate informazioni fare riferimento ai manuali delle centrali 1067 INSERIMENTO NELLA CENTRALE NOTA prima di aprire la centrale entrare in procedura di manutenzione onde evitare di far suonare le sirene ATTENZIONE la connessione dell interfaccia telefonica deve essere effettuata a centrale...

Page 3: ...legare il doppino ai morsetti LA e LB dell interfaccia non è necessario tener conto della polarità Sulla scheda 1067 002A è presente un LED giallo che indica l impegno della linea telefonica L interfaccia telefonica deve essere collegata a terra L interfaccia telefonica è già dotata di una protezione adatta alle normali esigenze come prescritto dalle normative Nel caso ci si trovasse ad operare in...

Page 4: ...ing manual WARNING In this document just a number of basic indications on the product are present Refer to the manuals of 1067 units for further more detailed information ENTERING THE UNIT NOTE Before opening the unit open the maintenance process in order to avoid the sirens to sound WARNING The telephone interface must be connected when the unit is not powered both network and battery are disconn...

Page 5: ...line to the LA and LB terminals of the interface it is not necessary to take polarity into account The 1067 002A board has a yellow LED to indicate if the telephone line is engaged The telephone interface must be grounded The telephone interface is already equipped with one protection that is appropriate to the regular needs as required by the existing regulations If there should be high risk of e...

Page 6: ...NG in dieser unterlage sind nur einige hauptsächliche angaben über das produkt enthalten Mehr und detailliertere Informationen finden Sie in den Handbüchern der 1067 Zentralen EINSTECKEN IN DIE ZENTRALE HINWEIS Vor dem Öffnen der Zentrale das Wartungsverfahren aufrufen um das Ertönen der Sirene zu unterbinden ACHTUNG Das Verbinden der Telefonschnittstelle darf immer nur bei nicht versorgter Zentra...

Page 7: ...s der Adern an die Anschlussstifte LA und LB der Schnittstelle hat die Polarität keine Bedeutung Auf der 1067 002A Karte befindet sich eine gelbe LED die anzeigt wenn die Telefonleitung genutzt wird Die Telefonschnittstelle muss geerdet werden Die Telefonschnittstelle ist gemäß den Vorschriften bereits mit einem den normalen Anforderungen entsprechenden Schutz ausgestattet Bei Betrieb in einem Ber...

Page 8: ...95 DS1067 056D Area tecnica servizio clienti 39 011 23 39 810 http www urmet com e mail info urmet com MADE IN ITALY URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 ...

Reviews: