![urmet domus 1058/010 Installation And User Manual Download Page 39](http://html1.mh-extra.com/html/urmet-domus/1058-010/1058-010_installation-and-user-manual_1062715039.webp)
DS1058-007A
39
8 DEFAULT
SETTINGS
System 1058/010 components go out of the default with following configurations:
Interface radio module 1058/010
Function
Programming
element
Default
Relay outputs 1÷8 polarisation
Jumper J1÷J8
0 V
Relay output SAB polarisation
Jumper J9
0 V
Relay output RF SAB polarisation
Jumper J10
0 V
Relay output BATT polarisation
Jumper J11
0 V
Relay output ON/OFF polarisation
Jumper J12
0 V
Relay output SYS ST polarisation
Jumper J13
0 V
Acquisition
DIP switch A1
OFF = normal function
Acquisition
DIP switch A2
OFF = normal function
Arm test
DIP switch A3
OFF = normal function
Output relay 1÷8 operation mode
DIP switch A4
OFF = bistable
Output relay 1÷8 typology
DIP switch A5
OFF = NC
Output relay SYS ST typology
DIP switch A6
OFF = NC
Output relay ON/OFF typology
DIP switch A7
OFF = NC
Output relay SAB/SAB.R/BATT typology
DIP switch A8
OFF = NC
Arming operation, subordinated radio module status,
on outputs 1÷8
DIP switch B1
ON = outputs not
subordinated
Enable Jamming detection
DIP switch B2
OFF = disarmed
Enable supervision (radio sabotage)
DIP switch B3
OFF = disarmed
Enable buzzer
DIP switch B4
OFF = enabled
Enable physical sabotage alarm
DIP switch B5
OFF = enabled
Input S polarity
DIP switch B6
OFF = negative polarity
Silence siren tamper for 1 hour
DIP switch B7
OFF = disabled
Silence sirens audio warnings
DIP switch B8
OFF = disabled
Microcontact 1058/201
Function
Programming
element
Default
Count shutter detector pulses
Jumper J1
OFF = 5 pulses in 10 s
Internal reed contact
Jumper J2
OFF = enabled
Type of external detector
Jumper J3
OFF = either NC contact
or auxiliary input not used
Outdoor siren 1058/405
Function
Programming
element
Default
Operation mode
DIP switch 1
OFF = normal
Reserved
DIP switch 2
OFF
Ringing duration
DIP switch 3-4
OFF-OFF = 3 minutes
Reserved
DIP switch 5
OFF
Reset memory
DIP switch 6
OFF = disabled
Reserved
DIP switch 7
OFF