Initial Installation
QUALIFIED INSTALLERS ONLY
m
anteL
R
equiRements
:
First determine what mantel height or depth you would like and use the graph to determine the minimum
corresponding dimension. Mantel graph dimensions are measured from the bottom of the appliance, if you
wish to reference the mantel height from the tiling edge subtract 38 5/8 inches (981mm) from the mantel
height depicted on the graph. If you plan to install a TV above your appliance refer to the appropriate section
for available options. It is acceptable to install a combustible mantel over top of the non-combustible board.
If you are activating the
c
ooL
s
uRFace
s
ystem
the mantel clearances may be reduced. Refer to
the second chart below for the reduced clearances.
*IMPORTANT - When using 5” x 8” venting the CSS MUST BE ACTIVATED prior to installation.
Use of 5x8 venting is NOT PERMITTED without the CSS activated.*
M
A
NT
EL
H
E
IG
H
T
M A N T E L D E P T H
38
40
42
44
46
48
2
4
6
8
10
12
14
4” MANTEL
12” MANTEL
8” MANTEL
Figure 54: Mantel Clearances - Non CSS
32
34
36
38
40
2
4
6
8
10
12
14
4” MANTEL
8” MANTEL
12” MANTEL
M
A
NT
EL
H
E
IG
H
T
M A N T E L D E P T H
Figure 55: Mantel Clearances - CSS Activated