TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
Please read and understand these instructions before installing.
Warning: This conversion kit shall be installed by a qualified service agency in accordance
with the manufacturer’s instructions and all applicable codes and requirements of the
authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified service agency is responsible for
the proper installation of this kit. The installation is not proper or complete until the
operation of the converted appliance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Kit Parts List for U37I Model:
1 - LP Stepper Motor w/ Hardware
1 -
Burner Orifices (
LP: #44)
1 - Pilot Orifice (NG: 0.2) or (LP: 0.14)
2 - Conversion Labels [included with unit]
Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are missing,
contact your dealer, distributor or courier company to have them replaced before starting this installation.
1. Disconnect the gas supply completely as well as any electrical power source before proceeding.
2. Remove safety screen, door trim, glass door, log grate, and burner (see
M
aIntenance
anD
s
erVIce
section of
Owner’s Manual
).
3.
Convert the existing burner orifice with the ones provided in this kit using a 1/2 inch socket.
c
onveRsion
k
it
i
nstaLLation
:
4.
Convert the existing pilot orifice using
a 7/16 inch wrench. Loosen the pilot
head, rotate counter clockwise and fully
remove. Remove the existing orifice and
replace with the one supplied in the
kit (Figure22). Re-install the pilot head
and tighten back to its original position
(Figure 23).
5.
Convert the gas valve:
a) Remove the existing stepper motor
using a T-20 screwdriver.
b) Remove the rubber diaphragm and
spring within; do not reuse.
c) Install the new stepper motor with
integrated diaphragm assembly using
longer hardware.
d) Plug new motor into existing wiring
harness.
Figure 21:
Orifice Location