16
Maintenance And Service
c
omPonent
a
ccess
:
1. Remove the safety screen (see
M
aIntenance
a
nD
s
erVIce
- r
eMoVe
s
afety
s
creen
on page 10).
2. Remove the door trim (see
M
aIntenance
a
nD
s
erVIce
- r
eMoVe
D
oor
t
rIM
on page 11).
3. Remove the glass door (see
M
aIntenance
anD
s
erVIce
- G
lass
D
oor
r
eMoVal
on page 11).
Loosen
F
use
R
ePLacement
:
1. Disconnect electrical power to the unit.
2. Remove component backpack (see
M
aIntenance
anD
s
erVIce
- c
oMPonent
B
ackPack
r
eMoVal
on page 13). If the
unit is already framed into the wall, refer to
M
aIntenance
anD
s
erVIce
- c
oMPonent
a
ccess
a
fter
I
nstallatIon
on page 15.
3. Remove the fuse cover by removing the two
T-20 screws (see Figure 20).
4. Remove the fuse by removing the two T-20
screws if they appear damaged.
5. Reconnect power to the unit.
Figure 18: Liner Retainer Removal
Figure 19: Right Liner Removal
Figure 20: Fuse Removal
4. Remove Porcelain Tray ((see
M
aIntenance
anD
s
erVIce
- G
lass
D
oor
r
eMoVal
on page 12).
5.
Remove light deflector (see Figure 14).
6. The components can be accessed behind the right liner panel. Loosen the two (2) bolts on the right liner
retainer using a 5/16” socket until it can be removed. See Figure 19.
7.
Remove the right liner from the firebox. See Figure 20.