Urbana U37GI Installation Manual Download Page 1

1

C#4001609

CERTIFIED TO: ANSI Z21.50 / CSA 2.22 VENTED DECORATIVE GAS APPLIANCES

CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

WARNING:  If the information in this manual is not followed exactly, a fire or explosion 

may result causing property damage, personal injury or loss of life. Installation and 

service must be performed by a qualified installer, service agency or the gas supplier.

C#4001609

U37GI

I N S TA L L AT I O N   M A N U A L

C-16473

Summary of Contents for U37GI

Page 1: ...ALTITUDES WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be perf...

Page 2: ...immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service m...

Page 3: ...be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54...

Page 4: ...al 12 Burner Shutter Cap Adjustment 13 Component Backpack Removal 13 Top Light Replacement 14 Component Access After Installation 15 Fuse Replacement 16 Burner Conversion 5 x 8 Venting 17 Fuel Convers...

Page 5: ...ation 5 x 8 44 Allowable Co Axial Vent Configurations 8 x 11 44 Exhaust Restrictor Setting 45 Horizontal Termination 46 Vertical Termination 47 Gas Line Connection and Testing 49 Electrical Requiremen...

Page 6: ...APPLIANCES CSA 2 17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES This Urbana U37I Decorative Appliance Is not a source of heat Has been certified for use with either natural gas or propane see rating label...

Page 7: ...24 1 4 616 24 7 8 632 22 1 4 565 22 3 8 568 8 x 11 Vent Remove the safety screen to access the rating label and lighting instructions They are attached to a length of chain and are never to be tamper...

Page 8: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only the remote supplied with this fireplace...

Page 9: ...Service Surround Panel Removal and Maintenance And Service Glass Door Removal Check the gasket material on the back of the glass making sure that it is attached and intact During a cold start up cond...

Page 10: ...temperature silicone around the perimeter of the door and install the new piece of glass with gasket Apply even pressure to the glass to allow the silicone to adhere to the gasket material Cleaning De...

Page 11: ...ove the glass door if the fireplace is not completely cold WARNING Never operate the fireplace with the glass door removed Figure 5 Door Trim Removal Door Trim Removal Figure 6 Glass Door Removal Figu...

Page 12: ...Figure 8 6 Remove the six 6 T 20 screws securing the buner tray to the firebox mounts see Figure 9 7 Remove the two 2 T 20 screws securing the orifice mount clamp onto the burner see Figure 10 To re i...

Page 13: ...e 11 Burner Cap Adjustment Component Backpack Removal The component backpack houses the valve IFC and fuses for the fireplace It is located on the back right side of the unit To remove the backpack an...

Page 14: ...ect them from the bulb assembly Remove assembly from unit then disconnect the ground wire Figure 13 Light Deflector Removal Figure 14 Top Light Removal Top Light Cover Light Gasket Light Retainer Top...

Page 15: ...Manifold Pressure Tap Power Vent Switch IFC Reset Burner Switch Backup Batteries Figure 17 Control Panel For convenience the fireplace comes pre wired for power vent applications If needed to switch...

Page 16: ...wall refer to Maintenance and Service Component Access After Installation on page 15 3 Remove the fuse cover by removing the two T 20 screws see Figure 20 4 Remove the fuse by removing the two T 20 sc...

Page 17: ...unit Carefully inspect all parts supplied with this conversion kit If any parts have been damaged or are missing contact your dealer distributor or courier company to have them replaced before startin...

Page 18: ...e see Figure 70 clockwise to decrease and counter clockwise to increase until the correct flame is achieved 12 Start the main burner and verify full range of adjustment using the UP DOWN key Confirm t...

Page 19: ...ere are four 4 nailing flanges to secure the unit to the framing they are assembled flat from the manufacturer see Figure 24 Flip the nailing flanges up 180 degrees and secure in place using the T 20...

Page 20: ...hape Figure 27 Top Standoff Install Top Standoffs Initial Installation QUALIFIED INSTALLERS ONLY 3 Install heat shield support using four 4 supplied T 20 screws see Figure 28 Figure 28 Top Standoff Su...

Page 21: ...activated To install the optional finishing edges 1 Remove the safety screen see Maintenance And Service Remove Safety Screen on page 10 2 Use a T 20 Screwdriver to remove the existing clean finishin...

Page 22: ...re two side covers attached via magnets Gently pull on the side cover until they detach and set them aside see Figure 31 4 There are thirteen 13 slotted fasteners that need to be loosened to adjust th...

Page 23: ...ol Surface System CSS has been correctly activated allowing heat in the chase to be vented This system keeps the front wall cool enough for any combustible materials The supplied non combustible board...

Page 24: ...view the guidelines in the previous sections to ensure your install is in accordance with the framing specifications Follow these instructions to activate the CSS feature Step 1 Remove the safety scre...

Page 25: ...yered on top of the supplied Non combustible board Supplied board not needed for thick non combustible finishes like rock Cool Surface System Extended Install By adjusting the cabinet back combustible...

Page 26: ...finish the CSS IMPORTANT When using 5 x 8 venting the CSS MUST BE ACTIVATED prior to installation Use of 5 x 8 venting is NOT PERMITTED without the CSS activated Figure 37 Framing Option 1 Initial In...

Page 27: ...em when using combustible materials Consider Option 3 Valance to work in conjunction with this option 2 MIN 3 2 51mm Minimum 121mm Minimum 6 152mm Minimum Wall Mounted Object 4 3 4 Optional False Ceil...

Page 28: ...out of the gap 121mm Minimum 3 76mm 15 381mm 4 3 4 5 127mm Minimum Minimum Maximum Option 3 Valance A valance may be desired to accentuate or hide the CSS outlet Consider framing option 1 or 2 to uti...

Page 29: ...Termination Sidewall Clearance 7 1 4 Mantle Clearance 6 Clearance reduced to 0 if installed with CSS activated 12 Non Combustible Facing Zone Combustible facing permitted if installed with CSS activat...

Page 30: ...installations A protective hearth is not required but highly recommended for the longevity of sensitive flooring materials in front of the appliance If masonry is to be used prepare the necessary fou...

Page 31: ...its height Example If the overhang height 8ft 2 4m then the overhang must extend at least 4ft 1 2m past each side of the fireplace opening Fireplace may only utilize the Cool Surface System CSS or an...

Page 32: ...or available options It is acceptable to install a combustible mantel over top of the non combustible board If you are activating the Cool Surface System the mantel clearances may be reduced Refer to...

Page 33: ...vent configurations It is recommended for vent lengths that pass through unheated spaces garages attics crawl spaces be insulated to minimize condensation NOTE At least 3 76mm of clearance is required...

Page 34: ...nt lengths that pass through unheated spaces garages attics crawl spaces be insulated to minimize condensation NOTE At least 3 76mm of clearance is required above vent when passing through an exterior...

Page 35: ...of combustible material Mantel It is not necessary to install a mantel but if one is desired the guidelines as shown in Initial Installation Mantel Requirements Floor The unit must be raised to accom...

Page 36: ...ine the minimum allowable mantel depth Recess Mantel Installation Always maintain minimum clearances see Figure 55 The total depth of the TV and wall mount as well as the recess depth will determine t...

Page 37: ...ter line extended above me ter regulator assembly I 3 ft 91 cm 3 ft 91 cm Radial clearance around service regulator vent outlet Table 2 Vent Termination Clearances Vent Termination Restrictions WARNIN...

Page 38: ...mbustible materials are directly above the first 90 elbow 5 127 mm of clearance is necessary Vertical Pipe to the Side Walls Horizontal Pipe to the Sides Bottom Above First Elbow Above Subsequent Elbo...

Page 39: ...ved venting parts table Termination Heat Deflector required for all 5x8 installations supplied The following termination restrictions only apply to 5 x 8 venting configurations These restrictions are...

Page 40: ...1 Vent Part Numbers Town Country Metal Fab Sure Seal Description Metal Fab Urbana 8DV6 6 pipe length TCVT 811X12 8DV12 50 4110 12 pipe length TCVT 811X18 18 pipe length TCVT 811X24 8DV24 50 4108 24 pi...

Page 41: ...S DVA BVS VSS 5DT VS VSK 5DHVS DVSK 5DVS Vinyl siding standoff sheild 58DVA WT3 58DVA WTU3 5WT 5DT WT 5DWT 5DWT 5DWT11 Wall thimble 58DVA SC SQSC SC 5DT SC 5DSC 5DSC Storm collar 58DVA WFS 5DT FS 5DFS...

Page 42: ...zontal run for each 45 elbow 1 feet 45 7cm must be subtracted Restrictor Setting Find the point on the graph where your vent configuration will terminate Remember to consider elbows in the HORIZONTAL...

Page 43: ...is manual for restrictor details Your climate and altitude may alter what restrictor is required for your particular application Figure 60 5 x 8 LP Vent Graph Vertical vent height does not account for...

Page 44: ...the proper diagram depending on if your unit uses Natural Gas Figure 61 or Propane Figure 62 Figure 61 8 x 11 NG Vent Graph Figure 62 8 x 11 LP Vent Graph Manufacturer Trade Name Model ICC EXCELDirect...

Page 45: ...Figure 63 The proper setting is crucial for an efficient burn and best possible flame appearance It may be necessary to deviate from the recommended setting as different altitudes and climates can var...

Page 46: ...yl siding For installations using 5x8 venting a vinyl standoff is mandatory for all combustible building exterior finishes See page 40 for more information 5 Horizontal pipes must be supported every 3...

Page 47: ...Do not pack air spaces with insulation Step 2 Set the appliance in the desired location Drop a plumb bob down from the ceiling to the appliance flue exit and mark the location where the vent will pen...

Page 48: ...9 Over 20 12 to 21 12 8 2 44 Figure 67 Height of Vertical Termination Reference Table 9 45 elbows x2 Wall strap Plumber s tape connected to wal strap Figure 68 Multi Story Vent Pipe Installation NOTES...

Page 49: ...supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for...

Page 50: ...receptacle wiring CAUTION When servicing controls label all wires prior to disconnection Wiring errors can cause improper and dangerous operation Verify proper operation after servicing If any of the...

Page 51: ...e important for optimal operation of the appliance Proper media installation will result in a flame similar to what is shown below If the flame is too tall or too blue in colour remove the porcelain t...

Page 52: ...ith black glass media or with the vermiculite media supplied The placement of the logs is not arbitrary If they are positioned incorrectly the flames can be impinged and will not burn correctly creati...

Page 53: ...e Rear Right Log as shown above STEP 4 Figure 77 Log Set Installation Step 5 STEP 5 Figure 78 Log Set Installation Step 6 STEP 6 Figure 79 Log Set Installation Step 7 STEP 7 Figure 80 Log Set Installa...

Page 54: ...media The placement of the river rocks may vary as desired but they can t placed into the recessed burner area The twigs can be positioned only in the burner area as shown If they are positioned inco...

Page 55: ...on the valve and pilot burner assembly orifice Pilot will not remain lit 7 Day Shutdown The pilot has been in operation for 7 continuous days without main burner operation Turn fireplace ON to reset...

Page 56: ...ith manual Terminal may be re circulating flue gases Check to see if terminal is on correctly May need to install high wind termination cap Contact dealer Blue Flames The heater has just been started...

Page 57: ...e 50 4205 Valve Access Panel Gasket 50 4204 15 Firebox Door Roller Set 2pcs 50 4220 16 Firebox Door Spring Relief Assembly 50 4221 17 Firebox Door Handle Set 4pcs 50 4223 18 Valve Pressure Test Port 5...

Page 58: ...58 Parts Diagram 2 1 13 12 6 5 8 7 3 4 11 10 16 21 25 20 9 14 17 22 18 23 24 15 19...

Page 59: ...of original purchase must be provided by you or the dealer including serial number Exclusions An expanded list of exclusions is available at www urbanafireplaces com warranty html This warranty does n...

Page 60: ...________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in wc MAIN BURNER ORIFICE __________ DMS PILOT OR...