Section 1 — Introduction

Section 1 

Introduction

The SetPoint 501 and 501s Controllers are microprocessor-based controls

that are designed to sense the air temperature in a specific area and

increase the comfort level of that area as well as increase the energy 

efficiency of the heating system. The 501s will also monitor 

slab temperature.

SetPoint 501s

SetPoint 501

Summary of Contents for SetPoint 501

Page 1: ...739 Fax 952 891 1409 Web www uponor usa com E mail learnmore uponor usa com Uponor Ltd 655 Park Street Regina SK S4N 5N1 Tel 888 994 7726 Fax 800 638 9517 Web www uponor ca E mail info uponor ca INSTA...

Page 2: ...ration 8 Mode 8 Section 3 Navigating the Menus View Menu 9 Adjust Menu 9 Section 4 Troubleshooting Error Messages 11 Section 5 Technical Data SetPoint 501 13 SetPoint 501s 14 SetPoint 501 and 501s Con...

Page 3: ...lers are microprocessor based controls that are designed to sense the air temperature in a specific area and increase the comfort level of that area as well as increase the energy efficiency of the he...

Page 4: ...tic tab and pull the top of the front cover so that it pivots around the bottom edge of the base See Figure 1 Mounting the Base 1 Install the controller on an interior wall of the desired zone approxi...

Page 5: ...e controller 1 Connect the 24VAC power to the R and C terminals on the controller This connection provides power to the microprocessor and display of the controller 2 When wiring an optional sensor to...

Page 6: ...settings in the controller including those required to match the controller to the mechanical system and devices The User access level allows the end user to adjust the temperature settings 7 Section...

Page 7: ...an air sensor the on time for the Heat relay is calculated to satisfy the requirements of the air sensor Slab or Floor Sensor Only Operation 501s Only When operating with only a slab or floor sensor...

Page 8: ...rrecting the fault press any button to clear the error message See Figure 25 11 Section 4 Troubleshooting Figure 22 Figure 23 Figure 24 Figure 25 ROOM HEAT This displays the desired temperature for he...

Page 9: ...31 F 30 to 55 C 90 RH non condensing Power Supply 24VAC 10 50 60 Hz 1 VA Relay 24VAC 2 A 13 Section 5 Technical Data SENS Shr The optional sensor has a short circuit Locate and repair the problem as d...

Page 10: ...21mm Approvals CSA C US meets ICES and FCC regulations for EMI RFI Ambient Conditions Indoor use only 22 to 131 F 30 to 55 C 90 RH non condensing Adjustment Range 34 to 122 F 1 to 50 C for Slab or Fl...

Reviews: