Technopel Compact Pellet Boiler Installation and User’s Manual
DANGEROUS
There should be no defective or suspicious electrical lines in the boiler room.
The 230 V electrical connection of the control panel should be connected to the mains
via an automatic fuse (W automat).
SAFETY PRECAUTIONS
The boiler must be connected to a chimney in accordance with the features specified in the manual
and the relevant regulations. Chimney should provide required stack draught values of the boiler.
The boiler should not operate without a flue connection and without an adequate stack draught.
Faulty electrical cables in the place of the installed boiler must be removed.
In the case of boiler replacement in boiler rooms, the former boiler must be disassembled or
chimney connection must be cut off and the cut point must be
isolated. It should not connect more than one boiler to the
same chimney.
Chimney of Technopel Pellet Boilers is individually used as
well. The chimney and fresh air suction line can be taken out
from the back of the boiler room. The flue cap must put to the
outlet section of the chimney. It can be made of metal or heat-resistant material.
Please do not overload the boiler, do not open the boiler door, and also don’t feed pellets into the
combustion chamber. Gearbox operating and stopping period should be set into the system such as a
program. These settings depend on many parameters such as the boiler flue characteristics (stack
draught), working environment, thermal comfort requirement, and isolation.
All electrical and water systems must be installed by the plumbers of authorized technical services.
Installation must be done by the plumbers in order to comply with all legal and technical regulations.
DANGEROUS
This product must connect to the mains with the groundling process.
DANGEROUS
The electrical installation should be done by the technician in compliance with all legal
and technical regulations, according to the items in the manual.
ALERT
Never disconnect the power supply while the boiler is operating.
Cold water should not be added directly to the overheated boiler for any cooling purpose. This can
cause noise, overheating voltage, and indirect permanent damage.