Technopel Compact Pellet Boiler Installation and User’s Manual
Installation with Single Serpentine Hot Water Storage Tank
Central Heating Flow Line (hot water) should be connected to the upper connection point of the
boiler and central heating return line (warm water) should be connected to lower connection point.
Pressure reducer, safety valve, and expansion tank must install to mains water.
Installation with Double Serpentine Hot Water Storage Tank
There are two different types of coil in double serpentine hot water storage tank. If we consider
connecting a continuously operate energy source (usually solar energy, geothermal, etc.) to the
lower serpentine, the pellet boiler
can be connected to the upper
serpentine. Pressure reducer, safety
valve, and expansion tank must
install to mains water.
Pump
Valve
3 Way Valve
Manometer
Filter
Checkvalve
Safety Valve
Automatic Air Purger
Pressure Reducer