81
Mask
Open Door If
Detection
Failed
The options are
On
and
Off
. Set the parameter based on the actual
conditions. The default value is
Off
.
After
On
is clicked, when the face recognition terminal detects that a
person does not wear a mask, a prompt is displayed on the GUI and a
voice prompt (please wear a mask) is played but the authentication
(face scan, IC card, ID card) and door opening result will not be
affected.
After
Off
is clicked, when the face recognition terminal detects that a
person does not wear a mask, a prompt is displayed on the GUI and a
voice prompt (please wear a mask) is played, and the door will not
open.
Temperature
Measurement
Temperature
Measurement
Measure Forehead Temperature: The forehead temperature will be
measured.
Measure Wrist Temperature: The wrist temperature will be
measured.
Do not need configuration. Terminal will automatically match the
temperature measurement mode when it is connected to the digital
detection module.
Authentication
Failed And
Open The Door
The options are
On
and
Off
. Set the parameter based on the actual
conditions. The default value is
Off
.
After
On
is clicked, when the digital detection module detects that a
person's temperature exceeds the preset temperature alarm threshold,
a prompt is displayed on the GUI and a voice prompt (abnormal
temperature) is played but the authentication (face scan, IC card, ID
card) and door opening result will not be affected.
After
Off
is clicked, when the digital detection module detects that a
person's temperature exceeds the preset temperature alarm threshold,
a prompt is displayed on the GUI and a voice prompt (abnormal
temperature) is played and the door will not open.
Temperature
Measurement
Range
Value range: [30–45]; default range: [34–42]
Configure the range based on actual application scenes.
Temperature
Alarm
Threshold
When the digital detection module detects a temperature higher than
the threshold configured here, the "abnormal temperature" alarm is
displayed on the GUI and the warning sound is played.
Value range: [30–45]; default value: 37.3
Temperature
Alert
The options are
On
and
Off
. Set the parameter based on the actual
conditions. The default value is
Off
.
After turning on the temperature alert, when body temperature is
within the range of temperature alert threshold and temperature alarm
threshold, high temperature alarm will be given to remind people to re-
detect.
Temperature
Alert Offset
Temperature Alert Threshold = Temperature Alarm Threshold -
Temperature Alert Offse
Alarm Output Configuration
High
Temperature
Alarm
The options are
On
and
Off
. Set the parameter based on the actual
conditions. The default value is
Off
.
After turning on the high temperature alarm, terminal will output a
high temperature alarm when digital detection module detects high
temperature.
Not Wearing
Mask Alarm
The options are
On
and
Off
. Set the parameter based on the actual
conditions. The default value is
Off
.
After turning on the not wearing mask alarm, terminal will output a not
wearing mask alarm when it detects people who not wearing a mask.
Blacklist Alarm
The options are
On
and
Off
. Set the parameter based on the actual
conditions. The default value is
Off
.
After turning on the blacklist alarm, terminal will output a blacklist