![UNIVIEW OET-213H User Manual Download Page 78](http://html.mh-extra.com/html/uniview/oet-213h/oet-213h_user-manual_1059615078.webp)
73
Figure7-44
Add Face Library Interface
Table7-19
Parameter Configuration
Parameter
Description and Configuration
Face Library Type
Set the parameter to either of the following options based on the actual conditions:
Employee Library
Visitor Library
Face Library Name
Enter a library name.
A string of 1 to 63 characters can be entered.
Check Template
Select a check template from the drop-down list. Check templates are added on the
interface.
1:N Match Threshold
The 1:N match is adopted in face recognition. When the match similarity reaches the threshold set
here, the authentication succeeds.
Verify Success
Linkage
Configuration
The options are as follows:
Open door
: After the authentication succeeds, a door opening signal is sent to trigger door
opening.
Voice Prompt
: A voice prompt is played after the authentication succeeds.
HMI Prompt
: A prompt is displayed on the GUI after the authentication succeeds.
Wiegand Output
: Data is output through the Wiegand interface after the authentication
succeeds.
Verify Failure
Linkage
Configuration
The options are as follows:
Voice Prompt
: A voice prompt is played after the authentication fails.
HMI Prompt
: A prompt is displayed on the GUI after the authentication fails.
Modifying a face library
(1)
Select a required face library and click
Edit
.
(2)
In the displayed
Edit Face Library
interface, modify parameters by referring to the description in
Adding a
face library
.