17
To change Mode:
a.
Press Mode key to select the desired mode (P = PPM; C = CPM, = =OFF)
To select Pulse Width (0 - 1400):
a.
Press PULSE WIDTH key (pulse width data in upper right corner of the
display will blink)
b.
Enter new data with number key, or edit with DELETE key then enter
data
c.
Press PULSE WIDTH key to exit Pulse Width
To select Pulse Rate (10 - 39999):
a.
Press PULSE RATE key (pulse rate data in the lower right corner of the
display will blink)
b.
Enter new data with number keys, or edit with DELETE key then enter
data
c.
Press PULSE RATE key to exit pulse rate
2.
Press the STORE key to exit laser control program mode.
3.
Repeat steps 1 and 2 until all desired combinations of laser control parameters are stored
in programs.
4.
After all of the desired pulse settings have been entered into programs, to permanently
save the programmed settings so that they will not be lost when the laser system is turned
off, press in rapid sequence the zero key, the store key, and the mode key. The entire
display will blink once to indicate that the programs are permanently stored.
OTE:
A Programs laser control parameters can be changed during engraving with out
problems but do not attempt to permanently store the settings as described in step
4 above while the system is engraving or the machine will lock up and have to be
reset.
To Recall Stored Laser Control Parameters:
During normal operation the laser system uses the laser control parameters which appear on the
display screen. To recalled a different set of stored laser control parameters for use, press in
sequence the program select key, the program number which contains the desired laser control
parameters and the store key.