background image

 

UniStream

®

 Display   

 

Product Diagram 

Front 

Rear 

 

 

 

Screen 

Protection  

A plastic sheet attached to the screen for protection. Remove it 

during installation.   

Ethernet port 

 

Enables you to connect the Display to the UniStream PLC via 

Ethernet cable. 

USB Host port 

Provides the interface for system updates and system log access. 

Power Supply 

Input  

Connection point for the Display power source.  
Connect the Terminal Block supplied with the kit to the end of the 

power cable. 

   

 

 

 

Unitronics 

 

Summary of Contents for UniStream

Page 1: ...configuration The series is available in three versions Pro Standard and Basic Note that a model number that includes B10 refers to Pro version e g USC B10 T24 B5 refers to Standard version e g USC B5 RA28 B3 refers to Basic version e g only for USC B3 T20 Page 2 contains a comparison table detailing the features offered by the different models Exact features are detailed in the product specificat...

Page 2: ...sh drive This enables the end user to implement certain actions such as to update firmware update network settings download applications extract log files and more Differences between B10 B5 and B3 Feature B10 Pro B5 Standard B3 Basic I O Expansion via Uni I O Yes No Remote I O Expansion via Ethernet I O Adapter URB Up to 8 1 VFD 32 2 MicroSD Yes No Add on COM modules 3 2 System Memory 6GB 3GB 3GB...

Page 3: ...product should be installed only by qualified personnel Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not connect disconnect the device when power is on Environmental Considerations Ventilation 10mm space is required between the device top bottom edges and the enclo...

Page 4: ...stallation 2 Ethernet port Enables you to connect the Display to the UniStream PLC via Ethernet cable 3 USB Host port Provides the interface for system updates and system log access 4 Power Supply Input Connection point for the Display power source Connect the Terminal Block supplied with the kit to the end of the power cable 4 Unitronics ...

Page 5: ... Display Installation Space Considerations Allocate space for the device access to ports For exact dimensions please refer to the Mechanical Dimensions shown below Mechanical Dimensions USL 050 B05 Unitronics 5 ...

Page 6: ...UniStream Display USL 070 B05 Panel Mounting NOTE Mounting panel thickness must be less or equal to 5mm 0 2 Ensure that the space considerations are met 6 Unitronics ...

Page 7: ...0 35 N m 3 5 kgf cm Wiring This equipment is designed to operate only at SELV PELV Class 2 Limited Power environments All power supplies in the system must include double insulation Power supply outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the Neutral or Line signal of the 110 220VAC to device s 0V point Do not touch live wires All wiring activities should be perf...

Page 8: ...each functional ground point to the earth of the system preferably to the metal cabinet chassis Use the shortest and thickest wires possible less than 1m 3 3 in length minimum thickness 14 AWG 2 mm2 Connect the power supply 0V to the earth of the system Earthing the cables shield Connect the cable shield to the earth of the system preferably to the metal cabinet chassis Note that the shield must b...

Page 9: ... 1 After the device is powered on select the Network tab at the bottom of the screen 2 Enter the IP Address for the VNC connection a password if one is required by the VNC server edit the timeout if required and then tap Apply To add connections tap the Connection scroller and repeat the steps above 1 When a connection is defined the Connect button is activated tap it to initiate the VNC connectio...

Page 10: ... information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no event shall Unitronics be liable for any special incidenta...