UniStream

®

 Display   

 
Programming 

Software 

All-in-One UniLogic software for hardware configuration, 

communications, PLC and HMI applications; free download. 

HMI 

All UniStream® PLCs can display HMI screens on the following devices:  

 

UniStream Display (USL)  

 

UniStream Modular HMI panel (USP) 

 

UniStream Built-in (on the panels integral to the device) 

 

Any device screen that supports VNC 

HMI 

HMI screens are designed in UniLogic. In addition to the HMI screens, 

UniStream® PLCs offer built-in HMI features, including: 

 

UniApps™: Access & edit data, monitor, troubleshoot, debug, 

and more 

 

Security: Multi-level password protection 

Alarms: Built-in system, ANSI/ISA standards 

USB Action 

files 

Programmers can create files in UniLogic and save them to a USB mass 

storage device, such as a flash drive. This enables the end user to 

implement certain actions such as to update firmware, update network 

settings, download applications, extract log files and more. 

Differences 

between 

B10, B5, 

and B3 

Feature 

B10 Pro 

B5 Standard  B3 Basic 

I/O Expansion via Uni-I/O  

Yes 

No 

Remote I/O Expansion via 

Ethernet  I/O Adapter (URB) 

Up to 8 

VFD 

32 

MicroSD 

Yes 

No* 

Add-on COM modules 

System Memory 

6GB 

3GB 

3GB 

 

MODBUS Slaves 

Unlimited 

Up to 8 

Ethernet/IP Scanners 

16 

Ethernet/IP Adapters 

32 

Web Server 

Yes 

No 

No 

SQL Client 

Yes 

No 

No 

 

MQTT 

Yes 

 

PID Loops 

64 

 

Data Sampler/Trends 

Yes 

No 

 

CSV files: creating/ reading  

Yes 

No 

 

FTP, server/client 

Yes 

No 

 

Saving Data Tables to SD 

Yes 

No* 

 

Screenshots 

Yes 

No 

 

Sending email attachments 

Yes 

No 

 

USB device (programming port) 

Yes 

No** 

* Note that B3 models do not support features requiring SD cards. In addition, Alarm 

History is not retained after PLC reset. 
** Note that B3 models may be programmed only via Ethernet cable.  

 

 

 

 

Unitronics 

 

Summary of Contents for UniStream

Page 1: ...configuration The series is available in three versions Pro Standard and Basic Note that a model number that includes B10 refers to Pro version e g USC B10 T24 B5 refers to Standard version e g USC B5 RA28 B3 refers to Basic version e g only for USC B3 T20 Page 2 contains a comparison table detailing the features offered by the different models Exact features are detailed in the product specificat...

Page 2: ...sh drive This enables the end user to implement certain actions such as to update firmware update network settings download applications extract log files and more Differences between B10 B5 and B3 Feature B10 Pro B5 Standard B3 Basic I O Expansion via Uni I O Yes No Remote I O Expansion via Ethernet I O Adapter URB Up to 8 1 VFD 32 2 MicroSD Yes No Add on COM modules 3 2 System Memory 6GB 3GB 3GB...

Page 3: ...product should be installed only by qualified personnel Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not connect disconnect the device when power is on Environmental Considerations Ventilation 10mm space is required between the device top bottom edges and the enclo...

Page 4: ...stallation 2 Ethernet port Enables you to connect the Display to the UniStream PLC via Ethernet cable 3 USB Host port Provides the interface for system updates and system log access 4 Power Supply Input Connection point for the Display power source Connect the Terminal Block supplied with the kit to the end of the power cable 4 Unitronics ...

Page 5: ... Display Installation Space Considerations Allocate space for the device access to ports For exact dimensions please refer to the Mechanical Dimensions shown below Mechanical Dimensions USL 050 B05 Unitronics 5 ...

Page 6: ...UniStream Display USL 070 B05 Panel Mounting NOTE Mounting panel thickness must be less or equal to 5mm 0 2 Ensure that the space considerations are met 6 Unitronics ...

Page 7: ...0 35 N m 3 5 kgf cm Wiring This equipment is designed to operate only at SELV PELV Class 2 Limited Power environments All power supplies in the system must include double insulation Power supply outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the Neutral or Line signal of the 110 220VAC to device s 0V point Do not touch live wires All wiring activities should be perf...

Page 8: ...each functional ground point to the earth of the system preferably to the metal cabinet chassis Use the shortest and thickest wires possible less than 1m 3 3 in length minimum thickness 14 AWG 2 mm2 Connect the power supply 0V to the earth of the system Earthing the cables shield Connect the cable shield to the earth of the system preferably to the metal cabinet chassis Note that the shield must b...

Page 9: ... 1 After the device is powered on select the Network tab at the bottom of the screen 2 Enter the IP Address for the VNC connection a password if one is required by the VNC server edit the timeout if required and then tap Apply To add connections tap the Connection scroller and repeat the steps above 1 When a connection is defined the Connect button is activated tap it to initiate the VNC connectio...

Page 10: ... information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no event shall Unitronics be liable for any special incidenta...

Reviews: