Electrical installation
DS 400-2
04/2019 - V01
32
Au
xi
liar
y v
olt
ag
e c
on
ne
ct
io
n
4.9
Auxiliary voltage connection
Mains potential-free auxiliary dc voltage
24 V=
±
10 % / 2 A
The auxiliary voltage
- is galvanically connected with the logic voltage
- is galvanically isolated from all internal supply voltages of the device
- has internal regenerating fuses
- has an EMC filter
DS-BAx-DPC/E-DS-400-Hilfsspannung
External fuse only for line protection.
Input voltage
24 V DC X1:4
GND24 X1:3
Residual ripple
10 %
Inrush current
2 A
Nominal current
0.8 A
Attention:
In addition to the internal supply current (0.8 A) the sum of the
output currents (DOUT) must be provided by the mains module
24 V.
If the auxiliary voltage is inferior to 20 V - even in case of short-time
voltage drop-outs - the internal mains module is switched off.
Any data of the RAM are deleted!
The speed and the position command values are set to zero
and any calibrated data are deleted.
The LED signal for the state "OK" is dark.