![Unitek DS-405.2 Manual Download Page 21](http://html1.mh-extra.com/html/unitek/ds-405-2/ds-405-2_manual_4041149021.webp)
Mechanical Installation
DS 400-2
04/2019 - V01
20
Dim
en
sio
ns
- a
cc
esso
rie
s
3.3
Dimensions - accessories
EMV-Filter
DS/DS-400-Filter1 Grounding on case back
Type
Voltage Current
Dimensions
Weight
V~
A~
HxBxT mm
kg
F250-V-B90-16
1x250
1x16
45x90x40
0,4
F400-V-B108-16 3x480
3x16
90x140x55
0,8
F400V-B150-25
3x480
4x25
130x180x80
2,4
Filters at high EMC requirements.
In residential and commercial areas or unknown locations.
Mount filter directly on the device.
Bus filter and input filter capacitors
are installed in the device.
Moto choke
DS/DS-400-Drossel
Type
Voltage Induction
Dimension
Weight
A
mH
HxBxT mm
kg
MDD 1.6a-5
5
1.9
95x54x108
MDD 1.6b-10
10
1
95x58x108
MDD 2b-20
20
0.8
128x80x140
Motor choke only for cable - shield capacitances > 5 nF.
Cable length approx. 25 m.
Regenerative discharge resistor in IP65
protection standard aluminium housing
Weight 1.1 kg
mounting screws M5x12
Caution:
The ballast resistor can get as hot as 200°C. Protect
the resistor against accidental touch when installing it.
Do not place any heat-sensitive components
directly at the resistor or in the hot airflow.
Mount resistor outside
BAWID-300-996