Basic - Information
Q3 15-150A
10/2018 - V01
6
Tech
n
ica
l Da
ta
2.4
Technical Data
Q3 400/450-x
Power connection:
360 … 440V~
Auxiliary voltage connection:
360 … 440V~, 200 … 250V~ or option
Output voltage:
max. ± 450V=
Cooling:
self cooling
Q3 400/450 -
15
25
40
Input current
A~
12
20
32
Output current -peak 5s
-continous
A=
A=
30
15
50
25
80
40
Elec. power
kW
6,75
11,25
18
Fuses
-input 3 St
-output 2 St
-field
ff
Aff
Aff
Af
20
25
10
30
50
10
50
63
10
Power chokes
Type
KD2-16
KD2,5-25
KD2,5-50
mH
0,9
0,7
0,4
Armature chokes
Type
EI135A-16
EI135B-24
EI150B-35
mH
33
16
8
Dimensions W x H x D
mm
290x230x190
290x230x190
290x230x190
Weight
kg
7,7
7,7
7,7
Q3 500/550-x
Power connection:
450 … 550V~
Auxiliary voltage connection:
360 … 440V~, 200 … 250V~ or option
Output voltage:
max. ± 550V=
Cooling:
self cooling
Q3 500/550 -
15
25
40
Input current
A~
12
20
32
Output current
- peak 5s
- continous
A=
A=
30
15
50
25
80
40
Elec. power
kW
8,25
13,75
22
Fuses
-input 3 St
-output 2 St
-field
ff
Aff
Aff
Af
20
25
10
30
50
10
50
63
10
Power chokes
Type
KD2-16
KD2,5-25
KD2,5-50
mH
0,9
0,7
0,4
Armature chokes
Type
EI135A-16
EI135B-24
EI150B-35
mH
33
16
8
Dimensions W x H x D
mm
290x230x190
290x230x190
290x230x190
Weight
kg