42
BAMOCAR D3
Me
a
su
re
me
n
t
Measurement values
Firmware 400 onwards
DC link voltage ( 400V)
BOMOCAR D3-400
DC link voltage
Parameter 0xa5
maximum voltage
460V
25088
battery voltage
370V
20179
over voltage – shut down
440V
24000
charging voltage
340V
18543
without power voltage
0V
0
standardization
1
54,54
Parameter 0xa5 = 54,54 x DC link voltage
DC-link voltage (700V)
BOMOCAR D3-700
DC link voltage
Parameter 0xa5
maximum voltage
800V
29195
battery voltage
700V
19088
over voltage – shut down
750V
28462
charging voltage
680V
24813
without power voltage
0V
0
standardization
1
36,49
parameter 0xa5 = 36,49 x DC link voltage
Current actual
BAMOCAR-D3
I-100%
Calibration rated current
i-device
Peak current
dc blocked
maximum value +/- 11bit
mv
num
Aeff
Aa=
num
Aa=
400 (700) -250/150
520
420
150
210
608
300
400 (700) -400/250
785
700
250
350
910
450
Basic reference values are stored in the parameter set.
Summary of Contents for BAMOCAR-D3
Page 3: ...3 Basic Information ...
Page 6: ...6 BAMOCAR D3 Attention nformation General ...
Page 12: ...12 BAMOCAR D3 Dimensions Screw for hex key BAMOCAR ...
Page 14: ...14 BAMOCAR D3 Assembly ...
Page 16: ...16 BAMOCAR D3 Block diagram ...
Page 17: ...17 Electrical Installation Block diagram ...
Page 18: ...18 BAMOCAR D3 Connection diagram ...
Page 19: ...19 Electrical Installation EMC ...
Page 26: ...26 BAMOCAR D3 ...
Page 33: ...33 Elektrical Installation Resolver connection Applicable only for BAMOCAR D3 xx RS Resolver ...
Page 34: ...34 BAMOCAR D3 Encoder TTL Encoder TTL Anschluß only BAMOCAR D3 IN ...
Page 35: ...35 Electrical Installation SIN COS 1Vss Anschluss only BAMOCAR D3 xx SC SIN COS 1vss ...
Page 36: ...36 BAMOCAR D3 Rotor sensor Anschluss with bl tacho only BAMOCAR D3 xx bl Rotor sensor ...
Page 45: ...45 Electrical Installation ...