background image

-5-

Installation

AVIS DE SÉCURITÉ

• SI VOTRE POÊLE EST MAL INSTALLÉ, UN INCENDIE PEUT PROVOQUER. POUR REDUIRE LE RISQUE D’INCENDIE, 

SUIVRE LES INSTRUCTIONS D’INSTALLATION.

• CONSULTER VOTRE SERVICE MUNICIPAL IMMEUBLE OU D’INCENDIE À PROPOS DE PERMIS, RESTRICTIONS ET 

INSTALLATIONS EXIGENCES DANS VOTRE RÉGION.

• UTILISATION DETECTEUR DE FUMÉE DANS LA PIÈCE OÙ EST INSTALLÉ VOTRE POÊLE.

• GARDER VÊTEMENTS ET LES MEUBLES LOIN DU POÊLE.

• NE JAMAIS UTILISER D’ESSENCE, ESSENCE-TYPE LANTERNE, KÉROSÈNE, ALLUME FLUIDE, OU LIQUIDES 

SIMILAIRES POUR COMMENCER OU “rafraîchir” UN FEU DANS CET APPAREIL. GARDEZ TOUS CES LIQUIDES 

LOIN DU CHAUFFAGE PENDANT QU’IL EST UTILISÉ.

• EN CAS D’UN FEU DE CHEMINEE, APPUYER SUR LE CONTRÔLE D’AIR EN POSITION FERMÉE POUR PRIVER LE 

FEU D’OXYGÈNE. APPELEZ LES POMPIERS.

• NE PAS CONNECTER À UN CONDUIT DE DISTRIBUTION D’AIR OU SYSTÈME.

• UNE SOURCE D’AIR FRAIS DANS LA PIÈCE OU L’ESPACE CHAUFFÉ EST FOURNI LORSQUE REQUIS.

POSITIONNEMENT DU POELE

Il est 

très important 

de localiser 

le poêle 

à bois 

le plus 

près possible 

de la 

cheminée, et 

dans un 

endroit qui 

favorisera la 

distribution de 

chaleur la 

plus efficace 

possible dans 

toute la 

maison. Le 

poêle doit 

donc être 

installé 

dans la pièce où le plus de temps est passé, et dans la salle la plus vaste possible. Rappelons que la chaleur 

des 

poêles à 

bois par 

rayonnement, la 

chaleur que 

nous ressentons 

lorsque nous 

sommes près 

d’un poêle 

à bois. 

Un poêle 

à bois 

fonctionne aussi 

par convection, 

qui est 

par le 

déplacement de 

l’air chaud 

vers le 

haut et 

son 

remplacement avec 

refroidisseur d’air. 

Si nécessaire, 

la distribution 

d’air chaud 

du poêle 

peut être 

facilitée par 

l’installation d’un ventilateur.

Le poêle 

à bois 

ne doit 

pas être 

relié à 

un système 

de distribution 

d’air chaud 

depuis une 

accumulation excessive 

de chaleur peut se produire.

Un poêle 

à bois 

ne doit 

jamais être 

installé dans 

un couloir 

ou près 

d’un escalier, 

car il 

peut bloquer 

le passage 

en cas d’incendie ou de ne pas respecter les dégagements requis.

COMMENT OUVRIR LE COUVERCLE SUPÉRIEUR

PRUDENCE! NE PAS OUVRIR OU FERMER LE TOP LORSQUE LE CHAUFFE EST 

CHAUD!

Pour ouvrir, 

saisissez le haut à l’avant ou à chaque coin et soulever tout 

le 

chemin jusqu’à 

la tige 

de support 

arrête le 

mouvement. Abaissez 

ensuite 

doucement le 

haut permettant 

à la tige 

de support 

pour se 

dépose dans 

la tasse, en tenant la partie supérieure ouverte.

Pour fermer, 

soulevez le haut jusqu’à ce que la tige de support est hors 

de la coupe. Tirez sur la tige avant et abaisser le couvercle fermé.

THERMODISQUE KIT POUR B36 SOUFFLEUR - EN OPTION

Souhaitez votre 

souffleur serait 

allumer et 

éteindre le 

chauffe devient 

chaud et 

le froid? Il peut 

avec ce kit 

optionnel de 

Stove États-Unis. Il se 

connecte en 

ligne avec votre cordon 

d’alimentation et monte 

à l’arrière 

de l’appareil.

 Lorsque 

le disque de pression 

atteint 120 degrés, 

le ventilateur 

se met automatiquement en marche et se met hors tension si elle atteint 

90 degrés. Consultez 

votre concessionnaire pour 

les détails ou appeler 

directement Poêle États-Unis.

Summary of Contents for WONDERWOOD

Page 1: ...IS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE MODEL B2941E B Certified to UL 1...

Page 2: ...ised BTU s are based on the first hour of operation at high burn rate burning cordwood CAUTIONS Hot while in operation Keep children clothing and furniture away Contact may cause skin burns Do not use...

Page 3: ...meter Black Steel pipe 24 gauge minimum and elbow s either adjustable1 or corrugated as necessary 1 2 Sheet Metal Screws 6 Inside Diameter Underwriters Laboratories UL listed Residential Type and Buil...

Page 4: ...t door knob is mounted on the inside of the cabinet door to facilitate shipping and must be removed and re installed for proper usage To get the cabinet door open place your hand under the cabinet fra...

Page 5: ...air distribution from the stove may be facilitated by the installation of a blower The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occ...

Page 6: ...rough a wall or partition of combustible construction is desired the installation must conform to CAN CSA B365 A flue pipe crossing a combustible wall must have a minimum clearance of 18 457 2mm To re...

Page 7: ...h removal opening If there is a horizontal section of chimney connector the floor protector should go under it and 2 inches beyond each side The floor protector should exceed the stove as follows 8 20...

Page 8: ...pipe should never exceed 8 to 10 2 4m to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system can be much longer and connected without problem to the ch...

Page 9: ...imney fires Note that it is the chimney and not the stove which creates the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendat...

Page 10: ...ame manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to...

Page 11: ...ociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed an...

Page 12: ...mney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing f...

Page 13: ...the forest floor should be considered wet and requires full seasoning time Standing dead wood can usually be considered to be about 2 3 seasoned Splitting and stacking wood before it is stored accele...

Page 14: ...lose the door If ignition of the piece is accomplished within 90 seconds from the time if was placed in the stove your wood is correctly dried If ignition takes longer your wood is damp If your wood h...

Page 15: ...brick Wood should be 3 to 4 below top of firebrick A burned out heat chamber may result Do not use artificial or wax logs Build fire on the floor of the stove Do not use additional grates or andirons...

Page 16: ...Timer SAT is used to control the duration of secondary air entering the stove When burning the stove be sure the timer is set to open Timer Knob past One Hour and Timer Lever to HI The SAT is only use...

Page 17: ...r the thermostat closes CAUTION Do not operate this heater with the loading door open Continuous operation with a door open will over heat the unit This heater is designed for Thermostatic and Burn Ra...

Page 18: ...given settings Visible smoke consist of unburned fuel and moisture leaving your stove Learn to adjust the air settings of your specific unit to produce the smallest amount of visible smoke Wood that h...

Page 19: ...the stove every time it is emptied in order to insure that no parts have been damaged in which case repairs must be performed immediately Inspect and clean the chimney and connector pipe periodically...

Page 20: ...20 1 2 3 9 8 7 6 5 4 12 11 10 42 41 28 13 14 17 15 16 17 20 19 23 22 24 25 26 27 29 30 31 32 33 37 38 34 35 36 40 39 21 43 44 Repair Parts...

Page 21: ...Assy Cabinet Door 1 16 89635 Knob Door 1 17 610837 Assy Cabinet Door Frame 1 18 83093 Latch Stove Spring 1 19 3070019 Jack Chain 1 20 67743 Assembly Thermostat 1 21 27291 Front Liner Top 1 22 610838...

Page 22: ...Door Hinge 1 6 88032 1 Rope Fiber 41 7 40764 Cast Door 1 8 27460 Ash Door Hinge 1 9 88032 1 Rope Fiber 27 5 8 9 6 3 2 1 7 4 In order to maintain warranty components must be replaced using original man...

Page 23: ...72 Brick Spacers 2 5 27564 Floor Back 1 6 610221 Floor Welded 1 7 610223 Cleanout Cover Weldment 1 1 2 3 4 6 5 7 In order to maintain warranty components must be replaced using original manufacturers...

Page 24: ...terruptions or uctuations of electrical power supply to the appliance Non USSC venting components hearth components or other accessories used in conjunction with the appliance USSC s obligation under...

Page 25: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Page 26: ...ence future Lors de l criture toujours donner le num ro de mod le complet qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage Lors de la commande des pi ces de rechange fournir...

Page 27: ...____________________ Company__________________________________________ N de t l phone ___________________________________ Po le Inspect Chemin e Swept Articles Remplac ________________________________...

Page 28: ...t autoris es et approuv es par crit par USSC et ou 9 les interruptions ou uctuations de l alimentation lectrique de l appareil Composants d vacuation des gaz composants de l tre ou accessoires utilis...

Page 29: ...Spacers Brick 2 5 27564 Etage Retour 1 6 610221 Etage soud 1 7 610223 Cleanout Cover Weldment 1 1 2 3 4 6 5 7 Afin de maintenir la garantie les composants doivent tre remplac s par des pi ces d origin...

Page 30: ...abricant de l appareil L utilisation de composants tiers annule la garantie Pi ces De Rechange L gende N de pi ce Description Qt 1 892767 Bouton en bois 2 2 27486 Poign e de porte 2 3 27462 Catch port...

Page 31: ...rte Cabinet 1 16 89635 Knob Porte 1 17 610837 Assy Cadre porte Cabinet 1 18 83093 Loquet Cuisini re Spring 1 19 3070019 Jack Chain 1 20 67743 Assembl e Thermostat 1 21 27291 Avant Liner Top 1 22 61083...

Page 32: ...21 Pi ces De Rechange 1 2 3 9 8 7 6 5 4 12 11 10 42 41 28 13 14 17 15 16 17 20 19 23 22 24 25 26 27 29 30 31 32 33 37 38 34 35 36 40 39 21 43 44...

Page 33: ...t nettoyer le tuyau de la chemin e et le connecteur p riodiquement pour l accumulation de cr osote ou obstructions GASKETING La porte ce cette unit utilise un joint de corde de 1po de diam tre Il est...

Page 34: ...fonctionnement appropri es La combustion secondaire ne peut avoir lieu que si le foyer est assez chaud V rifiez toujours l tat de cr osote une fois tous les deux mois et ont ramoner votre chemin e au...

Page 35: ...s po les bois l humidit dans le bois br l quitte le po le sous forme de vapeur Le pouvoir calorifique sup rieur c est lorsque l eau quitte le processus de combustion sous forme enti rement condens e D...

Page 36: ...LA CHAMBRE SI L AIR FROIDE FONCTIONNE LE JOURNAUX 5 Allumez le feu et fermez la porte de chargement 6 Attendez 3 5 minutes puis ajoutez du bois de chauffage assaisonn Voir la section concernant le car...

Page 37: ...e en position ouverte et verrouill e avec le levier d arr t de la minuterie est r gl e sur Salut et votre po le br lera de mani re optimale Il ne faut pas utiliser la minuterie sauf si vous souhaitez...

Page 38: ...ON br lez non trait seulement Bois contenant un conservateur des feuilles m talliques du charbon du plastique des ordures de soufre ou de l huile est dangereux pour l environnement et endommager l app...

Page 39: ...n air ouverte en tirant dessus et fermer la porte Si l allumage de la pi ce est r alis e dans les 90 secondes partir du moment qu il eut t plac dans le po le votre bois est bien s ch Si l allumage pre...

Page 40: ...s mat riaux peut causer des manations de fum es toxiques ou rendre le chauffage inefficace en raison de la fum e Le bois mort tomb des arbres doit tre consid r comme tant mouill et doit donc tre s ch...

Page 41: ...ible Commencez avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 304 mm de diam tre int rieur avec une isolation de 1 25 4 mm ou plus et un raccord de chemin e de 8 de diam...

Page 42: ...NERIE Assurez vous qu une chemin e en ma onnerie r ponde aux standards minimum de l Association nationale de protection contre les incendies NFPA en la faisant inspecter par un professionnel Assurez v...

Page 43: ...INE Lorsqu une chemin e m tallique pr fabriqu e est utilis e les instructions d installation du fabriquant doivent tre respect es Vous devez galement acheter aupr s du m me fabriquant et installer l e...

Page 44: ...effet de tirage les performances de votre po le d pendent directement du bon tirage de votre chemin e Les recommandations suivantes peuvent tre utiles pour l installation de votre chemin e 1 Ne conne...

Page 45: ...le de tuyau de chemin e doit tre conforme NFPA 211 Vous pouvez contacter la NFPA Association nationale de protection contre les incendies et demander la derni re dition du standard 211 de la NFPA Pour...

Page 46: ...de dessus PLANCHER PROTECTEUR Lorsque le chauffage est utilis sur un plancher combustible utiliser un protecteur Underwriters Liste de plancher qui est conforme aux normes UL UL 1618 et CAN ULC pour...

Page 47: ...ie de construction combustible est souhait e l installation doit tre conforme la norme CAN CSA B365 Un tuyau de raccordement traversant un mur combustible doit avoir un d gagement minimum de 18 457 2...

Page 48: ...le bois fonctionne aussi par convection qui est par le d placement de l air chaud vers le haut et son remplacement avec refroidisseur d air Si n cessaire la distribution d air chaud du po le peut tre...

Page 49: ...a vis de la machine et la poign e de porte 2 Placez le bouton sur l ext rieur de la porte de l armoire r installez la vis de la machine et serrer en faisant attention de ne pas d pouiller les fils dan...

Page 50: ...pe Diam tre noir en acier minimum de calibre 24 et le coude s soit adjustable1 ou ondul n cessaire Vis de 1 2 de t lerie 6 Diam tre int rieur Underwriters Laboratories UL num r s type r sidentiel et a...

Page 51: ...seront reconnaissants Les instructions concernant l installation de votre po le bois se conformer la norme UL 1482 11 R2015 et les normes ULC S627 00 Ce manuel d crit l installation et le fonctionnem...

Page 52: ...NCE S il vous pla t lire l int gralit de ce manuel avant d installer ou d utiliser votre nouvel appareil de chauffage Le non respect des instructions peut entra ner des dommages mat riels des blessure...