When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by 

enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 1) poor 

fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You can usually 

solve those problems related to 1 and 2. Customer service can solve problems relating to 3, 4 and 5. Refer to diagrams 

on page 25 to help locate indicated parts. For the sake of troubleshooting and using this guide to assist you, you should 

look at your heat level setting to see which light is flashing.

•  Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does 

not disconnect all power to the electrical components of the stove.

•  Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All other 

work should be done by a trained technician.

Display is Flashing “E1”

Possible Causes

Possible Remedies: (Unplug stove first when possible)

The stove is consuming too much fuel

Adjust the fuel adjuster slide (see the “How To Adjust The Fuel 

Adjuster” section of this manual). Close the slide about 1/4” after 

your stove cools down. Restart your stove. If your display shows 

E1 again, close the slide another 1/4” and restart.

The convection blower is overheating and 

tripping the internal temperature shutoff.

Clean any dust off of the windings and fan blade. If oiling the 

blower does not help, the blower may be bad.

The stove is being left on the highest setting for 

extended periods of time.

If operating the heater on the highest heat setting, the room 

temperature could increase enough and lead to potential 

overheating situations. If this happens try operating at a lower 

heat setting.

Fuel other than wood pellets is being burned in 

the stove.

This pellet stove is designed and tested to use wood pellets. 

Check for signs of fuel other than wood pellets. No other types 

of fuel have been approved for this pellet stove. If there are signs 

of other types of fuel being used, stop using them immediately.

Power surge or brown out situation.

A power surge, spike, or voltage drop could cause the high limit 

switch to trip. Check to see if a surge protector is being used on 

the stove. If not, recommend one to the customer.

High Limit Switch is malfunctioning.

If the other items check out OK, replace the high limit switch.

ATTENTION: This wood heater needs periodic inspection and repair for proper operation. It is against federal 

regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.

TROUBLESHOOTING GUIDE

Summary of Contents for 5501S

Page 1: ...or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use you...

Page 2: ...THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 5 lbs hr 0 7 kg hr Pellet size may effect the ac...

Page 3: ...Brand____________________________________________ If no Date of inspection of existing venting system _______________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...ed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory insta...

Page 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Page 6: ...N ULC standards Needs to extend 18 to the front 8 beyond each side of the unit A Back to Stove U S A 1 26 mm CAN 8 204 mm B Side to Stove U S A 6 153 mm CAN 8 204 mm C Front to Stove U S A 6 153 mm CA...

Page 7: ...to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using...

Page 8: ...t pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit periodic cle...

Page 9: ...e every 4ft 1 22m to make the system more stable If you live in an area that has heavy snowfall it is recommended that the installation be taller than 3ft 0 91m to get above the snowdrift line This sa...

Page 10: ...he two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual mode operates according to the 5 set level...

Page 11: ...FUEL INSTITUTE PFI Your pellet stove is designed to burn premium hardwood pellets that comply with the Pellet Fuels Institute PFI standard minimum of 40 lbs density per cubic ft 1 4 to 5 16 diameter...

Page 12: ...y hand NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this Avoid placing item...

Page 13: ...O NOT OVERFILL HOPPER TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate...

Page 14: ...e burn pot and the area inside the burn pot housing In particular it is advisable to clean out the holes in the burn pot to remove any build up that may prevent air from moving through the burn pot fr...

Page 15: ...aned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the nor...

Page 16: ...attempt to operate the unit with broken glass Replacement glass may be purchased from your U S Stove dealer If glass is broken follow these removal procedures 1 Remove the four 4 screws and glass ret...

Page 17: ...stove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered Before contac...

Page 18: ...ide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the internal tempe...

Page 19: ...Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Page 20: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 21: ...rating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure co...

Page 22: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 23: ...ve caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and c...

Page 24: ...Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blowe...

Page 25: ...2021 United States Stove Company 25 REPAIR PARTS 1 2 3 4 6 5 25 7 8 22 21 20 19 18 17 16 9 10 13 14 24 23 15 11 12 27 26...

Page 26: ...isc Room Air 1 23 80709 Room Blower 1 24 80549 Vacuum Switch 1 25 88176 Insulation Blanket 1 26 892685 Hearth Plate 1 27 892682 Door Assembly 1 80710 Wiring Harness 1 80711 Thermistor 1 Item Not Shown...

Page 27: ...2021 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Page 28: ...__________ Engineer Name ____________________________________ License No ________________________________________ Company __________________________________________ Telephone No ______________________...

Page 29: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Page 30: ...ed States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA D...

Page 31: ...7 80529 Moteur de vis sans fin 1 18 892665 Support de montage du moteur de la vis sans fin 1 19 892661 Soudure du bo tier de la tari re 1 20 892677 Tari re 1 21 892664 Douille d agitateur 1 22 80455 D...

Page 32: ...2021 United States Stove Company 25 1 2 3 4 6 5 25 7 8 22 21 20 19 18 17 16 9 10 13 14 24 23 15 11 12 27 26 SCH MA DES PI CES...

Page 33: ...lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des boi...

Page 34: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Page 35: ...tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v ri...

Page 36: ...erm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur...

Page 37: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Page 38: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion C...

Page 39: ...e po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 et recommencez Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinage...

Page 40: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant...

Page 41: ...N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre achet...

Page 42: ...son de chauffage Pour nettoyer la chemin e d connecter l vacuation du po le CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d vacuation Bien qu elles ne soient pas combustib...

Page 43: ...rieurs de l changeur de chaleur Pour acc der ces outs propres vous devez retirer les deux panneaux lat raux Les sorties propres sont fix es la chambre de combustion avec 2 vis 5 16 Retirez les feuille...

Page 44: ...ROP LA TR MIE AVERTISSEMENT DE SABOTAGE Ce po le bois a un taux de combustion faible minimum d fini par le fabricant qui ne doit pas tre modifi Il est contraire la r glementation f d rale de modifier...

Page 45: ...terrupteur ON OFF Assurez vous que le t moin vert s allume 2 Le registre de tirage doit tre compl tement ferm ou ouvert d un quart au maximum pendant le d marrage C est variable en fonction de votre i...

Page 46: ...ranul s de bois dur de qualit sup rieure conformes la norme PFI Pellet Fuels Institute densit minimale de 40 lb par pied cube diam tre de 1 4 5 16 moins de 8 200 BTU lb humidit inf rieure 8 en poids c...

Page 47: ...e fonctionnement du po le peut tre Manuel ou command par un Thermostat Des diodes distinctes gauche de l cran deux chiffres indiquent le mode de fonctionnement Manuel ou T stat Le po le doit tre en mo...

Page 48: ...une section de tuyau d au moins 3 pi 0 91 m doit tre ajout e avec un chapeau horizontal pour achever l installation Un support doit tre plac juste au dessous du chapeau de sortie ou raison d un suppor...

Page 49: ...e conduit d vacuation pour po le granul s est con u pour tre d mont aux fins de nettoyage et doit tre v rifi plusieurs fois au cours de la saison de chauffage Le conduit d vacuation pour po le granul...

Page 50: ...passer d au moins 36 po 914 mm au dessus de la fa ti re de la maison mobile elle doit tre install e avec un pare feu de plafond et un chapeau anti pluie homologu s UL En cas de d placement de la maiso...

Page 51: ...A Retour Cuisini re U S A 1 26 CAN 8 204 B C t po le U S A 6 153 CAN 8 204 C De l avant au po le U S A 6 153 CAN 8 204 D Retour Flue 2 51 D GAGEMENTS Votre po le granules a t test et r pertori pour u...

Page 52: ...ASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPR...

Page 53: ...bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connecter les install s en usine faisceaux de c blage sur le panneau de c...

Page 54: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 55: ...0 Ce manuel d crit l installation et le fonctionnement du po le bois USSC 5501S Cet appareil de chauffage respecte les limites d mission de bois de berceau de l Environmental Protection Agency des tat...

Page 56: ...ion de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRO...

Reviews: