TROUBLESHOOTING
UNIPOWER 600.12Q and 600.24Q
Troubleshooting
Causes
Remedies
3 short sound alarms
+
Blinking orange light
Output short circuit
Check the connections of your
devices to supply.
Overconsumption
Check that the power of the
connected device is compatible
with the power of the inverter or if
possible reduce the consumption of
the connected devices.
Long sound alarm
+
Blinking orange light
+
Unipower does not deliver current
anymore
Battery overvoltage
Check that the battery voltage is
compatible with the inverter.
Replace the battery if it is
defective.
Slow and short sound alarm
+ blinking green light
" Low battery warning"
Discharged battery
Recharge it and/or reduce the
consumption of the connected
devices before the inverter puts
itself in protection.
24V>230V inverter :
battery not suitable (12V
instead of 24V)
Replace your 12V battery by a 24V
battery.
Long sound alarm,
+
Blinking orange light
+
Unipower does not deliver current
anymore
Discharged battery
Recharge your battery or replace
it, if it is defective.
24V>230V inverter :
battery not suitable (12V
instead of 24V)
Replace your 12V battery by a 24V
battery.
Blinking green light
Overheating warning
Improve the ventilation, if possible
reduce the consumption of the
connected devices.
Unipower is off
Bad connection
Check the inverter/battery
connection.