WWW
.
UNITECK
.
FR
35/68
EN
TROUBLESHOOTING
UNIPOWER 350.12Q and 350.24Q
Troubleshooting
Causes
Remedies
Short sound alarm
Output short circuit
Check the connections of your
devices to supply
Overconsumption
Check that the power of the
connected device is compatible
with the power of the inverter or if
possible reduce the consumption of
the connected devices.
Blinking blue light
+ Short sound alarm
"Low battery warning"
Overconsumption or discharged
battery
Recharge it and/or reduce the
consumption of the connected
devices before the inverter puts
itself in protection.
24V>230V inverter :
Battery not suitable (12V
instead of 24V)
Replace your 12V battery by a 24V
battery
Long sound alarm
+
Unipower does not deliver
current anymore
Battery overvoltage
Check that the battery voltage is
compatible with the inverter.
Replace the battery if it is
defective.
Discharged battery
Recharge your battery or replace
it, if it is defective.
24V>230V inverter :
Non adapted battery (12V
instead of 24V)
Replace your 12V battery by a 24V
battery.
Blinking blue light
Overheating warning
Improve the ventilation, if possible
reduce the consumption of the
connected devices.
Short sound alarm
+
Unipower does not deliver
current anymore
Thermal protection : the inner
temperature of the inverter is
above 45°C
Stop the consumer. Let the inverter
cool down and improve the
ventilation.
Unipower is off
Bad connection
Control the inverter/battery
connection.
The fuse on the red cable is
melted.
Replace the fuse by another fuse of
the same size.
Summary of Contents for UNIPOWER 150.12Q