- 105 -
© 2020 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co., Ltd.
MS852B Plus User’s Manual
3.2.15.1 MSI Check Character
Different types of check characters are used with MSI bar codes. You can
program the scanner to read MSI bar codes with Type 10 check characters.
Default = Validate Type 10, but Don’t Transmit. When Check Character is set
to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes
printed with the specified type check character(s), and will transmit the
character(s) at the end of the scanned data. When Check Character is set to
Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes
printed with the specified type check character(s), but will not transmit the
check character(s) with the scanned data.
Validate Type 10, but Don’t Transmit*
Validate Type 10 and Transmit
Validate 2 Type 10 Characters, but Don’t Transmit
Validate 2 Type 10 Characters and Transmit
Validate Type 10 then Type 11 Character, but Don’t Transmit
Validate Type 10 then Type 11 Character and Transmit
Disable MSI Check Characters