background image

 

- 81 -

 

© 2020 unitech Electronics Co., Ltd. All rights reserved. 

unitech is a registered trademark of unitech Electronics Co., Ltd.

 

MS852B Plus User’s Manual 

 

3.2.2.7 Code 39 Code Page 

Code pages define the mapping of character codes to characters. If the data 
received does not display with the proper characters, it may be because the 
bar code being scanned was created using a code page that is different from 
the one the host program is expecting. If this is the case, scan the bar code 
below, select the code page with which the bar codes were created (

see ISO 

2022/ISO 646 Character Replacements

), and scan the value and the Save bar 

code from the 

Programming Chart

. The data characters should then appear 

properly. 
 

Code 39 Code Page

 

3.2.3 Interleaved 2 of 5 

 

Interleaved 2 of 5 On* 

 
 

Default All Interleaved 2 of 5    Settings 

 

Interleaved 2 of 5 Off 

 

 

 

 

Summary of Contents for MS852B Plus

Page 1: ...Bluetooth 2D Imager Barcode Scanner MS852B Plus User s Manual Version 1 0 ...

Page 2: ...Change Log Date Change Description Version 2020 4 17 first published version 1 0 ...

Page 3: ...ith the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference with radio communications However t...

Page 4: ...nce to co channel Mobile Satellite Systems Therefore it will only transmit on the 5 25 5 35 GHz 5 47 5 725 GHz and 5 725 5 850 GHz band when associated with an access point AP FCC Label Statement This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received...

Page 5: ...of health protection For body worn operation this device has been tested and meets the ICNIRP guidelines and the European Standard EN 62209 2 for use with dedicated accessories SAR is measured with this device at a separation of 0 5 cm to the body while transmitting at the highest certified output power level in all frequency bands of this device Use of other accessories which contain metals may n...

Page 6: ...t WEEE unitech has set up a policy and process to meet the EU directive 2002 96 EC and update 2003 108 EC concerning electronic waste disposal For more detailed information of the electronic waste disposal of the products you have purchased from unitech directly or via unitech s resellers you shall either contact your local supplier or visit us at https portal unitech eu public WEEE ...

Page 7: ...lus User s Manual Taiwan NCC Warning Statement 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用者 均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有 干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機需忍受合法通信或工業 科學及醫療用電波輻射性電機設備 之干擾 注意事項 1 使用過度恐傷害視力 2 使用30分鐘請休息10分鐘 2歲以下幼兒不看螢幕 2歲以上每天看螢幕不要超過 1小時 3 減少電磁波影響 請妥適使用 ...

Page 8: ...rescribed service operations The laser safety warning label required by the DHHS IEC for the unitech product s optional laser scanner module is located on the memory compartment cover on the back of the unit Laser information only applies to the products with laser components CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardo...

Page 9: ...nt charges are better than a fully uncharged battery Charging a partially charged battery does not cause harm to the unit Keep the battery cool Avoid hot vehicles For prolonged storage keep the battery at a 40 charge level Do not leave the battery uncharged and unused for an extended period of time the battery will wear out and the longevity of the battery will be at least half of one with frequen...

Page 10: ...d within the stated range of 0 C to 40 C Charging batteries outside of the specified range could damage the batteries and shorten their life cycle CAUTION Do not charge batteries at a temperature lower than 0 C This will and make the batteries unstable and dangerous Please use a battery temperature detecting device for a charger to ensure a safe charging temperature range CAUTION To ensure the uni...

Page 11: ...o 60 C however they may deplete more rapidly at higher temperatures It is recommended to store batteries at room temperature The message above only applies to the usage of the removable batteries For the products with non removable batteries without batteries please refer to the specification of each product Product Operation and Storage Notice The unitech product has applicable operation and stor...

Page 12: ...adapter or same specification of adapter to charge your unitech product Using the wrong power adapter can damage your unitech product The message above only applies to the product connected to the adapter For the products without using the adapters please refer to the specification of each product Hearing Damage Warning Zx 3 Warning The warning shall be placed on the equipment or on the packaging ...

Page 13: ...aat 19 5015 BB Tilburg the Netherlands http eu ute com China Japan Tel 86 59 2310 9966 Tel 81 3 35232766 E mail info cn ute com E mail info jp ute com Address Website Room401C 4F RIHUA International Mansion Xinfeng 3nd Road Huoju Hi tech District Xiamen Fujan China http cn ute com Address Website Kayabacho Nagaoka Building 8F 1 5 19 Shinkawa Chuo Ku Tokyo 104 0033 Japan http jp ute com Asia Pacifi...

Page 14: ... Limited Warranty are free from defects during normal use The warranty period is varied from each country Please consult with your supplier or unitech local office for actual length of warranty period to your purchased product Warranty becomes void if equipment is modified improperly installed or used damaged by accident or neglect or if any parts are improperly installed or replaced by the user ...

Page 15: ...rning x Worldwide Support xi Warranty Policy xii Chapter 1 Overview 1 1 1 Package 1 1 2 Product Detail 2 1 3 Specifications 4 1 4 Getting Started 7 1 5 Battery Charging 9 1 6 How to Replace Battery 10 1 7 LED Beeper Indicator 11 1 8 Firmware Update Procedure 13 1 9 Auto Presentation Mode 16 Chapter 2 Command Settings 17 2 1 Scanner Type 17 2 2 Operation Mode 17 2 3 System Reset Info 18 2 4 Data Me...

Page 16: ...Sending Inter Block Delay 27 2 18 HID Keyboard Character Delay 28 2 19 HID Keyboard Case 28 2 20 HID Keyboard Language 29 2 21 Save Buffer When Power Off 30 2 22 Control Character in Bar Code 30 2 23 End of Batch Sending Message 31 2 24 Setting Bar Codes Enable Disable 31 2 25 Scan mode 31 2 26 Suffix Selection 33 2 27 Aimer Delay 34 2 28 Aimer Mode 35 2 29 Centering 36 2 30 Video Reverse 38 2 31 ...

Page 17: ...ckage contents without cradle MS852B Plus Scanner with Battery USB Type C Charging Cable Quick Start Guide Regulatory Compliance Statements Note Charging with USB type C Cable The package contents with cradle MS852B Plus Scanner with Battery Interface Cable USB cable or RS232 cable Power Adapter Charging Cradle Quick Start Guide Regulatory Compliance Statements Note Charging with cradle NOTE The b...

Page 18: ... 2 2020 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 1 2 Product Detail Scanner details ...

Page 19: ... 3 2020 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual Cradle details Cradle Button ...

Page 20: ...075mm Printing Contrast Scale Minimum 20 Depth of Field DOF PCS 80 SYMBOLOGY X DIM TYPICAL RANGE Near Far13 mil UPC 1 34 in 3 4 cm 22 5 in 57 3 cm5 mil Code 39 2 76 in 7 cm 11 85 in 30 1 cm10 mil Code 39 1 14 in 2 9 cm 20 3 in 51 7 cm20 mil Code 39 1 38 in 3 5 cm 31 5 in 80 cm15 mil Code 128 1 34 in 3 4 cm 25 6 in 65 cm10 mil DM 2 84 in 7 2 cm 11 7 in 29 7 cm6 7 mil PDF417 3 3 in 8 4 cm 9 6 in 24 ...

Page 21: ...Coupon Code Coupon GS1 Code 32 PARAF 2D EAN UCC Emulation GS1 Data Bar TLC392D Stacked Codablock A Codablock F PDF417 MicroPDF4172D Matrix Aztec Code Data Matrix MaxiCode QR Code Chinese Sensible Han Xin Grid Matrix Dot CodePostal Australian Post British Post Canadian Post China Post Japanese Post Korea Post Netherlands Post Planet Code Postnet OCR Barcodes Support OCR barcodes Electrical Indicato...

Page 22: ...reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual Storage Temperature 40 C to 70 C 40 F to 158 F Relative Humidity 95 non condensing IP Rating IP42 Regulatory Approvals CE FCC BSMI VCCI NCC TELEC BQB ...

Page 23: ...r a short beep sound How to pair the scanner with the cradle 1 Firstly select the interface you want to communicate with your PC for USB RS232 cable connection please switch the interface switch to the left right side as below figure and then connect the cradle and the PC via the interface cable 2 Long press trigger key for 2 seconds to turn on the scanner And then put the scanner on the cradle to...

Page 24: ...lectronics Co Ltd MS852B Plus User s Manual The definition of Cradle Button Operation Long press 2 seconds to un pair with the scanner Long press 5 seconds to do reset default to the cradle Press the button to find the paired scanner Press power on plug in USB cable Enter bootloader mode for FW update ...

Page 25: ...ngly recommend charging the battery It takes approximately 5 hours to fully charge the battery To charge the scanner with without a cradle please follow the instructions below Please only use the USB type C cable which came with the package Charging through USB type C cable To charge MS852B Plus please connect scanner with host PC through USB type C cable Charging with the cradle Please charge you...

Page 26: ...ectronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 1 6 How to Replace Battery Please follow the below instruction to replace the scanner battery ...

Page 27: ...ED is in the center of top housing System Warning Error Red LED toggling every second for 5 seconds or until trigger key pressed BT is paired and disconnected to the host Solid Green Light Scanner in Auto Presentation Mode Green LED blinking every 2 seconds System busy with data scanning disabled Green LED toggling every second BT is connected to the host cradle ready to send data Solid Blue Light...

Page 28: ... receive data Solid Blue Light BT in pairing mode Blue LED toggling every second In cradle Firmware Update Mode White Light on In scanner Firmware Update Mode White LED toggling every second Scanner Beeper indicator Beeper Description Indication Scanner in Auto Operation Mode Power On with 1 Beep Scanner in Wedge Operation Mode Power On with 2 Beeps Scanner in Batch Operation Mode Power On with 3 ...

Page 29: ...counter this problem please use Tera Term V4 72 for firmware update 1 Switch Cradle interface to the USB serial interface away from RJ45 port 2 Press down the cradle button while plug in the USB cable into the computer 3 Cradle LED flashing white color when entering cradle firmware update mode 4 Open Tera Term and select Com port 5 The Tera Term screen pops up of ccccc strings and ready to update ...

Page 30: ...g blue color and then open the Tera Term and select the Com port to establish the connection 3 No need to power on the scanner and insert into the cradle 4 Press down Spacebar on the computer first while press down the scanner trigger key You will hear a Bi sound means scanner enters into the bootloader mode scanner flashing white LED 5 The Tera Term screen pops out of ccccc of strings 6 Select fr...

Page 31: ... check cradle firmware 1 Switch to USB HID interface close to RJ45 port and connect cradle to the computer and open word or note open Microsoft Word or note pad 2 Press and hold the cradle button until seeing factory default shown on the Screen How to check scanner firmware Please scan Send Info barcode below for setting Default USB HID Left Send Info ...

Page 32: ...Plus User s Manual 1 9 Auto Presentation Mode During the auto presentation mode scanner will be performing this mode automatically when scanner is on the cradle The scanner will switch to manual trigger mode when the scanner is removed from the cradle To enable auto presentation mode Scan the barcode below enable Disable Enable ...

Page 33: ...hapter 2 Command Settings 2 1 Scanner Type Note These settings are for cradleless mode only when the scanner connects to the host directly not through cradle To switch the different scanner type please do un pair first and then select the scanner type and redo Bluetooth connection 2 2 Operation Mode BT Keyboard BLE Keyboard BT SPP Auto Wedge Batch ...

Page 34: ...nitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 3 System Reset Info Factory Default Reset setting and Clean Bluetooth Link key information Reset Setting Reset setting but Keep Bluetooth Link key information Send Info ...

Page 35: ...Electronics Co Ltd MS852B Plus User s Manual 2 4 Data Memory Note To erase buffer scan Enter Auto Buffer Erase and then scan Erase To erase batch file scan Enter Batch File and then scan Erase Erase Free Buffer Drive Space Send Batch Enter Auto Buffer Erase Enter Batch File Erase Erase Last Data Entry ...

Page 36: ...d unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 5 BT SPP Setting Note Data ACK NAK is applied to Auto Operation Mode only Enable Auto Connection Disable Auto Connection Disable Data ACK NAK Enable Data ACK NAK ...

Page 37: ...User s Manual 2 6 Bluetooth Note If Higher Level RF Signal Checking is selected BLE communication will become more reliable but the distance will be shorter 2 7 Data Terminator CR CRLF LF None Null TAB BT BLE Un Pair Pair Enable Cradle Auto Pair Normal Level RF Signal Checking Higher Level RF Signal Checking Disable Cradle Auto Pair ...

Page 38: ...ronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 8 Auto Power Off After Idle 15 Minutes 5 Minutes 30 Minutes 2 Hours 4 Hours 6 Hours 1 Hour Disable ...

Page 39: ...td All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 9 Beeper Control 2 10 Good Read Indicator Beeper Vibrator None Beeper Vibrator Medium Volume High Volume Low Volume Mute ...

Page 40: ...ll rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 11 Connection Indicator None Beeper Vibrator Beeper Vibrator 2 12 System Setting Indicator None Beeper Vibrator Beeper Vibrator ...

Page 41: ... rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 13 System Warning Error Indicator None Beeper Vibrator Beeper Vibrator 2 14 Power On Indicator None Beeper Vibrator Beeper Vibrator ...

Page 42: ...itech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 15 Power Off Alarm Power Off Indicator None Beeper Vibrator Beeper Vibrator ...

Page 43: ...All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 16 Vibrator Control 2 17 Data Sending Inter Block Delay Enable Vibrator Disable Vibrator 10 ms 50 ms 100 ms 500 ms 1 Sec 3 Sec ...

Page 44: ...Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 18 HID Keyboard Character Delay 2 19 HID Keyboard Case 1 ms 5 ms 10 ms 20 ms 50 ms 100 ms To Upper To Lower Auto Trace ...

Page 45: ...rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 20 HID Keyboard Language German Japanese Danish Spanish US English UK English Swiss Swedish French ALT Mode Belgian Norwegian Italian ...

Page 46: ...a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 21 Save Buffer When Power Off 2 22 Control Character in Bar Code Note Partial Send only sends characters BS 0x08 TAB 0x09 CR 0x0D and ESC 0x1B Partial Send Don t Send Send Don t Save Save ...

Page 47: ... send message End of File Total Number CS 0xHHHH before the end of batch file sending Number is total entries in decimal format and 0xHHHH is 32 bit checksum in hex format Send Don t Send 2 24 Setting Bar Codes Enable Disable Enable Disable 2 25 Scan mode Before starting scan mode please make sure you disable the auto sensing mode Scan the bar code below to disable the auto sensing mode Disable Au...

Page 48: ...ation to detect bar codes When in Presentation Mode the LEDs remain dim until a bar code is presented to the scan engine then the aimer turns on and the LEDs turn up to read the code If the light level in the room is not high enough Presentation Mode may not work properly Scan the following bar code to program your scan engine for Presentation Mode 2 25 2 Aimer Mode This feature allows you to turn...

Page 49: ...r LED displays However the speed of scanning printed bar codes may be slightly lower when this mode is enabled You can enable Mobile Phone Reading for either a hand held device or for a hands free presentation application Hand Held Scanning Mobile Phone Streaming Presentation Mobile Phone 2 26 Suffix Selection 2 26 1 Add CR Suffix All Symbologies Scan the following bar code if you wish to add a ca...

Page 50: ... Suffixes 2 27 Aimer Delay The aimer delay allows a delay time for the operator to aim the scan engine before the picture is taken Use these codes to set the time between when the trigger is pulled and when the picture is taken During the delay time the aiming light will appear but the LEDs won t turn on until the delay time is over Default Off 200 milliseconds Off no delay 400 milliseconds ...

Page 51: ... own length for the duration of the delay scan the bar code below then set the time out by scanning digits 0 4 000 ms from the Programming Chart inside the back cover of this manual then scan Save Delay Duration 2 28 Aimer Mode This feature allows you to turn the aimer on and off When the Interlaced bar code is scanned the aimer is interlaced with the illumination LEDs Default Interlaced Off Inter...

Page 52: ...le codes are spaced closely together Using the Aimer Delay and Centering features the scanner can emulate the operation of older systems such as linear laser bar code scanners If a bar code is not touched by a predefined window it will not be decoded or output by the scan engine If centering is turned on by scanning Centering On the scan engine only reads codes that pass through the centering wind...

Page 53: ...ad It does not need to pass completely through the centering window Scan Centering On then scan one of the following bar codes to change the top and bottom of the centering window Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 for Top 60 for Bottom Centering On Top of Centering Window Bottom of Center...

Page 54: ...xample of this type of bar code Scan Video Reverse Only to read only inverted bar codes Scan Video Reverse and Standard Bar Codes to read both types of codes Note After scanning Video Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read menu bar codes Note Images downloaded from the unit are not reversed This is a setti...

Page 55: ...er along with the bar code data This group of bar code data and additional user defined data is called a message string The selections in this section are used to build the user defined data into the message string Prefix and Suffix characters are data characters that can be sent before and after scanned data You can specify if they should be sent with all symbologies or only with specific symbolo...

Page 56: ... may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in which you want them to appear on the output When setting up for specific symbologies as opposed to all symbologies the specifi...

Page 57: ...s 6A Step 3 Scan the 2 hex digits from the Programming Chart or scan 9 9 for all symbologies Step 4 Determine the hex value from the ASCII Conversion Chart for the prefix you wish to enter Note To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C To add a backslash you must scan 5C twice once to create the leading backslash and then to create the backslash i...

Page 58: ...Hex value from the Symbology Chart included in the Symbology Charts for the symbology to which you want to apply the prefix or suffix For example for Code 128 Code ID is j and Hex ID is 6A Step 3 Scan the 2 hex digits from the Programming Chart or scan 9 9 for all symbologies Step 4 Determine the hex value from the ASCII Conversion Chart for the prefix or suffix you wish to enter Note To add the C...

Page 59: ...You can clear a single prefix or suffix or clear all prefixes suffixes for a symbology If you have been entering prefixes and suffixes for single symbologies you can use Clear One Prefix Suffix to delete a specific character from a symbology When you Clear All Prefixes Suffixes all the prefixes or suffixes for a symbology are deleted Step 1 Scan the Clear One Prefix or Clear One Suffix symbol Step...

Page 60: ...d MS852B Plus User s Manual 2 31 1 5 To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then programs a carriage return suffix for all symbologies Add CR SuffixAll Symbologies ...

Page 61: ...ts reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 2 31 2 Prefix Selections Add Prefix Clear One Prefix Clear All Prefixes 2 31 3 Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes ...

Page 62: ...smit When this selection is enabled and function codes are contained within the scanned data the scan engine transmits the function code to the terminal Charts of these function codes are provided in Supported Interface Keys starting When the scanner is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Enable Disable ...

Page 63: ...y are entered However the following list presents the order in which formats are applied 1 Specific Terminal ID Actual Code ID Actual Length 2 Specific Terminal ID Actual Code ID Universal Length 3 Specific Terminal ID Universal Code ID Actual Length 4 Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Length 6 Universal Terminal ID Actual Code ID...

Page 64: ...st enter 3 digits For example scan 0 0 3 for an AT wedge Note 099 indicates all terminal types Step 4 Code I D In the Symbology Charts beginning on page A 1 find the symbology to which you want to apply the data format Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart If you wish to create a data format for all symbologies with the exception of some ...

Page 65: ...ack cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Clear all Data Formats This clears all data formats Save to exit and save your data format changes Discar...

Page 66: ... 50 2020 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual ...

Page 67: ...code Refer to the ASCII Conversion Chart Code Page 1252 for decimal hex and character codes Send a number of characters F2 Include in the output message a number of characters followed by an insert character Start from the current cursor position and continue for nn characters or through the last character in the input message followed by character xx Syntax F2nnxx where nn stands for the numeric ...

Page 68: ...o a particular character F3 Include in the output message all characters from the input message starting with the character at the current cursor position and continuing to but not including the search character ss followed by an insert character The cursor is moved forward to the ss character Syntax F3ssxx where ss stands for the search character s hex value for its ASCII code and xx stands for t...

Page 69: ...s moved forward to the beginning of the s s string Syntax B9nnnns s where nnnn stands for the length of the string and s s stands for the string to be matched The string is made up of hex values for the characters in the string Refer to the ASCII Conversion Chart Code Page 1252 for decimal hex and character codes B9 Example Send all characters up to a defined string Using the bar code above send a...

Page 70: ...he output message leaving the cursor in the current position Syntax F4xxnn where xx stands for the insert character s hex value for its ASCII code and nn is the numeric value 00 99 for the number of times it should be sent Refer to the ASCII Conversion Chart Code Page 1252 for decimal hex and character codes E9 and F4 Example Send all but the last characters followed by 2 tabs Send all characters ...

Page 71: ... character codes B9 and BA Example Look for the string AB and insert 2 asterisks Using the bar code above send all characters up to but not including AB Insert 2 asterisks at that point and send the rest of the data with a carriage return after Command string B900024142BA00022A2AF10D B9 is the Send all characters up to a string command 0002 is the length of the string 2 characters 41 is the hex va...

Page 72: ...string and does not include leading zeroes B3 and B4 Example Insert the symbology name and length Send the symbology name and length before the bar code data from the bar code above Break up these insertions with spaces End with a carriage return Command string B3F42001B4F42001F10D B3 is the Insert symbology name command F4 is the Insert a character multiple times command 20 is the hex value for a...

Page 73: ...e key modifier from the table below and nn is the key number from the Unicode Key Maps For example B501021F inserts an A on a 104 key U S style keyboard B5 the command 01 number of keys pressed without the key modifier 02 is the key modifier for Shift Right and 1F is the a key If a lower case a were to be inserted B501001F would be entered If there are three keystrokes the syntax would change from...

Page 74: ...rward and send the data Move the cursor forward 3 characters then send the rest of the bar code data from the bar code above End with a carriage return Command string F503F10D F5 is the Move the cursor forward a number of characters command 03 is the number of characters to move the cursor F1 is the Send all characters command 0D is the hex value for a CR The data is output as 4567890ABCDEFGHIJ CR...

Page 75: ...with a 1 If a bar code matches move the cursor back to the beginning of the data and send 6 characters followed by a carriage return Using the bar code above Command string FE31F7F2060D FE is the Compare characters command 31 is the hex value for 1 F7 is the Move the cursor to the beginning command F2 is the Send a number of characters command 06 is the number of characters to send 0D is the hex v...

Page 76: ...8xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 for decimal hex and character codes F8 Example Send bar code data that starts after a particular character Search for the letter D in bar codes and send all the data that follows including the D Using the bar code above Command string F844F10D F8 is the Search forward for ...

Page 77: ...tring Syntax B0nnnnS where nnnn is the string length up to 9999 and S consists of the ASCII hex value of each character in the match string For example B0000454657374 will search forward for the first occurrence of the 4 character string Test Refer to the ASCII Conversion Chart Code Page 1252 for decimal hex and character codes B0 Example Send bar code data that starts after a string of characters...

Page 78: ...ch the input message forward for the first non xx character from the current cursor position leaving the cursor pointing to the non xx character Syntax E6xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 for decimal hex and character codes E6 Example Remove zeroes at the beginning of bar code data This example shows a bar ...

Page 79: ...to 15 different characters starting at the current cursor position as the cursor is advanced by other commands When the FC command is encountered the suppress function is terminated The cursor is not moved by the FB command Syntax FBnnxxyy zz where nn is a count of the number of suppressed characters in the list and xxyy zz is the list of characters to be suppressed FB Example Remove spaces in bar...

Page 80: ...racters to be replaced and xx2 defines replacement characters continuing through zz1 and zz2 E4 Example Replace zeroes with CRs in bar code data If the bar code has characters that the host application does not want included you can use the E4 command to replace those characters with something else In this example you will replace the zeroes in the bar code above with carriage returns Command stri...

Page 81: ...on character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 for decimal hex and character codes Compare characters B2 Compare the string in the input message to the string s If the strings are equal move the cursor forward past the end of the string Syntax B2nnnnS where nnnn is the string length up to 9999 and S consists of the ASCII hex value of each character i...

Page 82: ...Only output the data if the bar code begins with a number If you want only data from bar codes that begin with a number you can use EC to check for the number Command string ECF10D EC is the Check for a number command F1 is the Send all characters command 0D is the hex value for a CR If this bar code is read the next data format if there is one will be used on the data If there is no other format ...

Page 83: ...ple Only output the data if the bar code begins with a letter If you want only data from bar codes that begin with a letter you can use ED to check for the letter Command string EDF10D ED is the Check for a non numeric character command F1 is the Send all characters command 0D is the hex value for a CR If this bar code is read the next data format if there is one will be used on the data If there ...

Page 84: ... 5 select 9999 for all lengths Enter FE41B8 to compare and discard Code 128 bar codes that begin with the letter A Syntax B8 Note The B8 command must be entered after all other commands The Data Format must be Required in order for the B8 command to work If Data Format is On but Not Required bar code data that meets the B8 format is scanned and output as usual Because the data format needs to be O...

Page 85: ... are not transmitted If a data format is not found for that symbol the prefixes and suffixes are transmitted Data Format Required Keep Prefix Suffix Scanned data is modified according to your data format and prefixes and suffixes are transmitted Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted If you wish to process...

Page 86: ...or tone If you scan the Data Format Non Match Error Tone Off bar code data that doesn t conform to your data format is not transmitted and no error tone will sound If you wish to hear the error tone when a non matching bar code is found scan the Data Format Non Match Error Tone On bar code Default Data Format Non Match Error Tone On Data Format Non Match Error Tone On Data Format Non Match Error T...

Page 87: ...al 2 32 8 Primary Alternate Data Formats You can save up to four data formats and switch between these formats Your primary data format is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below Primary Data Format Data Format 2 Data Format 1 Data Format 3 ...

Page 88: ...te data format then reverts to the format you have selected above either Primary 1 2 or 3 For example you may have set your device to the data format you saved as Data Format 3 You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan Data Format 1 bar code below The next bar code that is scanned uses Data Format 1 then reverts back to Data Format 3 Single Scan Primary ...

Page 89: ...xed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes included in the explanation of the symbology then sc...

Page 90: ...MS852B Plus User s Manual 3 2 1D 3 2 1 Codabar Codabar On Default All Codabar Settings Codabar Off 3 2 1 1 Codabar Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Default Don t Transmit Transmit Don t Transmit ...

Page 91: ...er indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar bar codes printed with a check character and will transmit this character at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read Codabar bar codes printed ...

Page 92: ...racter In this case the two messages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters On Off Require 3 2 1 4 Codabar Message Length Scan the bar codes below to change the message length Refer to Message Length Des...

Page 93: ...td MS852B Plus User s Manual 3 2 2 Code 39 Code 39 On Default All Code 39 Settings Code 39 Off 3 2 2 1 Code 39 Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Default Don t Transmit Transmit Don t Transmit ...

Page 94: ...cter but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this character at the end of the scanned data Default No Check Character No Check Character Validate but Don t Transmit Validate and Transmit 3 2 2 3 Code 39 Message Length Scan the bar co...

Page 95: ...anner encounters a Code 39 bar code with the append trigger character s it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger The data is then transmitted in the order in which the bar codes were read FIFO Default Off Off On 3 2 2 5 Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies This s...

Page 96: ...e 39 decoding is enabled certain character pairs within the bar code symbol will be interpreted as a single character For example V will be decoded as the ASCII character SYN and C will be decoded as the ASCII character Default Off Character pairs M and N decode as a minus sign and period respectively Character pairs P through Y decode as 0 through 9 Full ASCII Off Full ASCII On ...

Page 97: ...cause the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements and scan the value and the Save bar code from the Programming Chart The data characters should then appear properly Code 39 Code ...

Page 98: ... will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit No Check Digit Validate but Don t Transmit Validate and Transmit 3 2 3 2 Interleaved 2 of 5 Message Length Scan the bar codes below ...

Page 99: ...s Manual 3 2 4 Code 93 Code 93 On Default All Code 93 Settings Code 93 Off 3 2 4 1 Code 93 Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Page 100: ...e read deleting the first space from each The scanner transmits the appended data when it reads a Code 93 bar code that starts with a character other than a space Default Off Off On 3 2 4 3 Code 93 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a...

Page 101: ...raight 2 of 5 Industrial Off 3 2 5 1 Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length 3 2 6 Straight 2 of 5 IATA two bar start stop Straight 2 of 5 IATA Industrial On Default...

Page 102: ...cs Co Ltd MS852B Plus User s Manual 3 2 6 1 Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length ...

Page 103: ...Matrix 2 of 5 Matrix 2 of 5 On Default All Matrix 2 of 5 Settings Matrix 2 of 5 Off 3 2 7 1 Matrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Page 104: ...heck Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits One Check Digit Two Check Digits 3 2 8 2 Code 11 Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Minimum Message Length...

Page 105: ...Blood Transfusion ISBT ratified a standard for communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood products 2 the current recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 t...

Page 106: ...Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length 3 2 9 3 Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer When the scanner encounters a Code 128 bar code with the append trigger character s it buffers Code 128 bar codes until it reads a Code 128 bar code that ...

Page 107: ...oes not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements and scan the value and the Save bar code from the Programming Chart The da...

Page 108: ...t UPC A bar codes to EAN 13 see Convert UPC A to EAN 13 3 2 10 1 UPC A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off 3 2 10 2 UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not...

Page 109: ...dds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda 3 2 10 4 UPC A Addenda Required When Required is scanned the scanner will only read UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda Default Not Required Not Required Required 2 Digit Addenda Off 2 Digit Addenda On 5 Digit Addenda Off 5 Digit Addenda On ...

Page 110: ...either transmitted or discarded based on the setting you are using for UPC A Addenda Required Set the length in milliseconds for this timeout by scanning the bar code below then setting the timeout from 0 500 milliseconds by scanning digits from the Programming Chart then scanning Save Default 100 Addenda Timeout 3 2 10 6 UPC A Addenda Separator When this feature is on there is a space between the...

Page 111: ...extended coupon code in a single scan it transmits both as one symbology Otherwise it transmits the first coupon code it reads If you scan the Require Concatenation code the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data No data is output unless both codes are read Default Off 3 2 10 8 Coupon GS1 DataBar Output If you scan coupons that have...

Page 112: ...se the UPC E0 On selection If you need to read codes that lead with the 1 number system use UPC E1 Default On Code UPC A On Default All UPC E Settings Code UPC A Off 3 2 11 1 UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off Off On 3 2 11 2 UPC E0 Addenda Required When Required is scanned the scanner will only read UPC E bar codes that have addenda Default ...

Page 113: ...the data from the bar code and the data from the addenda When turned Off there is no space Default On On Off 3 2 11 4 UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On On Off 3 2 11 5 UPC E0 Leading Zero This feature allows the transmission of a leading zero 0 at the beginning of scanned data To prevent transmiss...

Page 114: ...n adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda 3 2 12 UPC E1 Most U P C bar codes lead with the 0 number system For these codes use UPC E0 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off Off On 2 Digit Addenda Off 2 Digit Addenda On 5 Digit Addenda Off 5 Digit Addenda On ...

Page 115: ...nvert UPC A to EAN 13 When UPC A Converted to EAN 13 is selected UPC A bar codes are converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A Do not Convert UPC A UPC A Converted to EAN 13 3 2 13 2 EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the sc...

Page 116: ...a This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda 3 2 13 4 EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required Not Required Required 2 Digit Addenda Off 2 Digit Addenda On 5 Digit Addenda Off 5 Digit Addenda On ...

Page 117: ...data from the bar code and the data from the addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code On Off 3 2 13 6 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off On Off 3 2 14 EAN JAN 8 EAN JAN 8 On Defau...

Page 118: ...unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 3 2 14 1 EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off ...

Page 119: ...da This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda 3 2 14 3 EAN JAN 8 Addenda Required When Required is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required Not Required Required 2 Digit Addenda Off 2 Digit Addenda On 5 Digit Addenda Off 5 Digit Addenda On ...

Page 120: ...nitech Electronics Co Ltd MS852B Plus User s Manual 3 2 14 4 EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On On Off 3 2 15 MSI MSI On Default All MSI Settings MSI Off ...

Page 121: ...ad MSI bar codes printed with the specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character s but will not transmit the check character s with the scanned data Validate Type 10 but Don t Transmit Validate...

Page 122: ...nual 3 2 15 2 MSI Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length 3 2 16 NEC 2 of 5 NEC 2 of 5 On Default All NEC 2 of 5 Settings NEC 2 of 5 Off ...

Page 123: ...t but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit No Check Digit Validate and Transmit Validate but Don t Transmit 3 2 16 2 NEC 2 of 5 Message Length Scan the bar codes below to change ...

Page 124: ...s Manual 3 2 17 GS1 128 GS1 128 On Default All GS1 128 Settings GS1 128 Off 3 2 17 1 GS1 128 Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Page 125: ... full ASCII start stop pattern 1 When Original Telepen Output is selected the scanner reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output AIM Telepen Output Original Telepen Output 3 2 18 2 Telepen Message Length Scan the bar codes below to change the message length Refer to Message Length Descripti...

Page 126: ...tronics Co Ltd MS852B Plus User s Manual 3 3 2D 3 3 1 GS1 DataBar Omnidirectional GS1 DataBar Omnidirectional On Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional Off 3 3 2 GS1 DataBar Limited GS1 DataBar Limited On Default All GS1 DataBar Limited Settings GS1 DataBar Limited Off ...

Page 127: ...lt All GS1 DataBar Expanded Settings GS1 DataBar Expanded Off 3 3 3 1 GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Minimum Message Length Maximum Message Length 3 3 4 PDF 417 PDF 417 On Default All PDF 417 Settings PDF 417...

Page 128: ...efer to Message Length Description for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 Minimum Message Length Maximum Message Length 3 3 5 MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a si...

Page 129: ...the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 Minimum Message Length Maximum Message Length 3 3 7 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allo...

Page 130: ...GS1 128 or GS1 linear component Default UPC EAN Ver sion Off Note If you scan coupons that have both UPC and GS1 DataBar codes you may wish to scan and output only the data from the GS1 DataBar code See Coupon GS1 DataBar Output for further information On Off 3 3 7 2 GS1 Composite Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description for addi...

Page 131: ... 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 If GS1 DataBar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 DataBar AIM ID em If GS1 Code Expansion Off is scanned retail code expansion is di...

Page 132: ...inked Code 39 TLC39 This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component All bar code readers are capable of reading the Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off On Off ...

Page 133: ... Manual 3 3 9 QR Code QR Code On Default All QR Code Settings QR Code Off 3 3 9 1 QR Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 7089 Minimum Default 1 Maximum Default 7089 Minimum Message Length Maximum Message Length ...

Page 134: ...es Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On On Off 3 3 9 3 QR Code Page QR Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is...

Page 135: ... 10 Data Matrix Data Matrix On Default All Data Matrix Settings Data Matrix Off 3 3 10 1 Data Matrix Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 3116 Minimum Default 1 Maximum Default 3116 Minimum Message Length Maximum Message Length ...

Page 136: ...append the data from several Data Matrix bar codes together before transmitting them to the host computer When the scanner encounters an Data Matrix bar code with the append trigger character s it buffers the number of Data Matrix bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Defa...

Page 137: ...er characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements and scan the value and the Save bar code from the Programming Chart The data characters should then app...

Page 138: ...tronics Co Ltd MS852B Plus User s Manual 3 3 11 1 MaxiCode Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Minimum Message Length Maximum Message Length ...

Page 139: ...Chinese Sensible Han Xin Code Han Xin On Default All Han Xin Settings Han Xin Off 3 3 12 1 Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Minimum Message Length Maximum Message Length ...

Page 140: ... postal codes and 2D postal code combinations that are allowed Only one 2D postal code selection can be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off 2D Postal Codes Off 3 3 13 1 Single 2D Postal Codes Australian Post On British Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet C...

Page 141: ...rk of unitech Electronics Co Ltd MS852B Plus User s Manual Postal 4i On Postnet On Postnet with B and B Fields On InfoMail On 3 3 13 2 Combination 2D Postal Codes InfoMail and British Post On Postal 4i and Postnet with B and B Fields On Postnet and Postal 4i On Planet Code and Postal 4i On ...

Page 142: ...gent Mail Bar Code On Planet Code Postnet and Postal 4i On Planet Code and Postnet On Planet Code Postal 4i and Intelligent Mail Bar Code On Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postal 4i and Postnet with B and B Fields On Postnet and Intelligent Mail Bar Code On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 143: ...d B Fields On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code and Intelligent Mail Bar Code On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet On Planet Code Postnet and Intelligent Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 144: ...election allows you to specify whether the check digit should be transmitted at the end of Planet Code data Default Don t Transmit Transmit Check Digit Don t Transmit Check Digit 3 3 13 4 Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data Default Don t Transmit Transmit Check Digit Don t Transmit Check Digit ...

Page 145: ...lian 4 State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Combination C and N Tables causes the field to be interpreted using either the C or N Tables Bar Ou...

Page 146: ...f 5 China Post Hong Kong 2 of 5 On Default All China Post Hong Kong 2 of 5 Settings China Post Hong Kong 2 of 5 Off 3 3 14 1 China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length...

Page 147: ... Code must be off Trioptic Code is used for labeling magnetic storage media On Off 3 3 16 Codablock A Codablock A On Default All Codablock A Settings Codablock A Off 3 3 16 1 Codablock A Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 Minimum M...

Page 148: ... Codablock F Settings Codablock F Off 3 3 17 1 Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Minimum Message Length Maximum Message Length 3 3 17 2 Label Code The standard Label Code is used in libraries Default Off On Off ...

Page 149: ... 3 18 Aztec Code Aztec Code On Default All Aztec Code Settings Aztec Code Off 3 3 18 1 Aztec Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 3832 Minimum Default 1 Maximum Default 3832 Minimum Message Length Maximum Message Length ...

Page 150: ...the proper number of codes is reached the data is output in the order specified in the bar codes Default On On Off 3 3 18 3 Aztec Code Page Aztec Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is ...

Page 151: ...Chinese Sensible Han Xin Code Han Xin On Default All Han Xin Settings Han Xin Off 3 3 19 1 Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Minimum Message Length Maximum Message Length ...

Page 152: ...Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length 3 3 20 2 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data Default Don t ...

Page 153: ... 137 2020 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 3 3 21 Dotcode Dotcode On ...

Page 154: ...nd AIM ID Linear Symbologies AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Codabar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z i 69 EAN Em 0 1 3 4 d 64 EAN 13 including Bookland EAN E0 d 64 EAN 13 with Add On E3 d ...

Page 155: ...3 f 66 Straight 2 of 5 Industrial S0 f 66 MSI Mm 0 1 g 67 Telepen Bm t 74 UPC 0 1 2 3 8 9 A B C AIM Honeywell Symbology ID Possible modifiers m ID Hex UPC A E0 c 63 UPC A with Add On E3 c 63 UPC A with Extended Coupon Code E3 c 63 UPC E E0 E 45 UPC E with Add On E3 E 45 UPC E1 X0 E 45 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 5 35 ...

Page 156: ... 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 3 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 Postal Symbologies AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Australian Post X0 A 41 British Post X0 B 42 Canadian Post X0 C 43 China Post X0 Q 5...

Page 157: ...s Non printable ASCII control Keyboard Control ASCII CTRL X Mode Windows Mode Control X Mode On KBDCAS2 DEC HEX Char Control X Mode Off KBDCAS0 CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Copy 4 04 EOT ALT Break CTRL D Bookmark 5 05 ENQ CTRL Make CTRL E Center 6 06 ACK CTRL Break CTRL F Find 7 07 BEL Ente...

Page 158: ...CTRL X Mode Windows Mode Control X Mode On KBDCAS2 DEC HEX Char Control X Mode Off KBDCAS0 CTRL X CTRL X function 19 13 DC3 Backspace CTRL S Save 20 14 DC4 Back Tab CTRL T 21 15 NAK F12 CTRL U 22 16 SYN F1 CTRL V Paste 23 17 ETB F2 CTRL W 24 18 CAN F3 CTRL X 25 19 EM F4 CTRL Y 26 1A SUB F5 CTRL Z 27 1B ESC F6 CTRL 28 1C FS F7 CTRL 29 1D GS F8 CTRL 30 1E RS F9 CTRL 31 1F US F10 CTRL 127 7F NP Enter...

Page 159: ...ifferent from the one the host pro gram is expecting If this is the case select the code page with which the bar codes were created The data characters should then appear properly Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Great Britain UK ISO IEC 646 04 7 87 France ISO IEC 646 69 3 83 Germany ISO IEC646 21 4 84 Switzerland ISO IEC 646 CH 6 86 Sweden Finland e...

Page 160: ... 7E US 0 1 CA 54 95 à â ç ê î ô é ù è û CA 18 96 à â ç ê É ô é ù è û JP 28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keyboard Honeywell CodePage ISO IEC 646 Na...

Page 161: ... 98 62 b 35 23 67 43 C 99 63 c 36 24 68 44 D 100 64 d 37 25 69 45 E 101 65 e 38 26 70 46 F 102 66 f 39 27 71 47 G 103 67 g 40 28 72 48 H 104 68 h 41 29 73 49 I 105 69 i 42 2A 74 4A J 106 6A j 43 2B 75 4B K 107 6B k 44 2C 76 4C L 108 6C l 45 2D 77 4D M 109 6D m 46 2E 78 4E N 110 6E n 47 2F 79 4F O 111 6F o 48 30 0 80 50 P 112 70 p 49 31 1 81 51 Q 113 71 q 50 32 2 82 52 R 114 72 r 51 33 3 83 53 S 11...

Page 162: ...Ç up arrow 0x48 129 81 ü down arrow 0x50 130 82 é right arrow 0x4B 131 83 ƒ â left arrow 0x4D 132 84 ä Insert 0x52 133 85 à Delete 0x53 134 86 å Home 0x47 135 87 ç End 0x4F 136 88 ˆ ê Page Up 0x49 137 89 ë Page Down 0x51 138 8A Š è Right ALT 0x38 139 8B ï Right CTRL 0x1D 140 8C Œ î Reserved n a 141 8D ì Reserved n a 142 8E Ž Ä Numeric Keypad Enter 0x1C 143 8F Å Numeric Keypad 0x35 144 90 É F1 0x3B...

Page 163: ...r s Manual 157 9D Numeric Keypad 0x4A 158 9E ž Numeric Keypad 0x37 159 9F Ÿ ƒ Caps Lock 0x3A 160 A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shift 0x36 165 A5 Ñ Print Screen n a 166 A6 ª Tab 0x0F 167 A7 º Shift Tab 0x8F 168 A8 Enter 0x1C 169 A9 Esc 0x01 170 AA ª Alt Make 0x36 ...

Page 164: ...nded PS2 Scan Code 171 AB Alt Break 0xB6 172 AC Control Make 0x1D 173 AD Control Break 0x9D 174 AE Alt Sequence with 1 Character 0x36 175 AF Ctrl Sequence with 1 Character 0x1D 176 B0 177 B1 178 B2 179 B3 180 B4 181 B5 µ 182 B6 183 B7 184 B8 185 B9 186 BA º 187 BB 188 BC 189 BD 190 BE 191 BF 192 C0 À 193 C1 Á 194 C2 Â 195 C3 Ã 196 C4 Ä 197 C5 Å í 198 C6 Æ 199 C7 Ç 200 C8 È 201 C9 É 202 CA Ê 203 CB...

Page 165: ...reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó 212 D4 Ô 213 D5 Õ 214 D6 Ö 215 D7 216 D8 Ø 217 D9 Ù 218 DA Ú 219 DB Û 220 DC Ü 221 DD Ý 222 DE Þ ...

Page 166: ...ed DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code 223 DF ß 224 E0 à α 225 E1 á ß 226 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ µ 231 E7 ç τ 232 E8 è Φ 233 E9 é Θ 234 EA ê Ω 235 EB ë δ 236 EC ì 237 ED í φ 238 EE î ε 239 EF ï 240 F0 ð 241 F1 ñ 242 F2 ò 243 F3 ó 244 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù 250 FA ú 251 FB û 252 FC ü ⁿ 253 FD ý 254 FE þ 255 FF ÿ ...

Page 167: ... 151 2020 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual Appendix B Programming Chart 0 1 2 3 4 5 6 7 8 9 ...

Page 168: ... 152 2020 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual A B C D E F ...

Page 169: ...d unitech is a registered trademark of unitech Electronics Co Ltd MS852B Plus User s Manual Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again Save Reset Discard ...