GENERAL

This completely assembled unit includes a well-insu-
lated cabinet, a DX cooling coil with copper tubes and
aluminum fins, 1 expansion valve, 1 distributor, throw-
away filters, a centrifugal blower, a blower motor con-
tactor and a small holding charge of Refrigerant-22.  A
blower motor with adjustable drive is factory mounted
on every unit.

Supplemental resistance heaters, a supply air plenum,
a return air grille and a base are available as accesso-
ries for field installation.

The unit is shipped in the vertical position with a verti-
cal air discharge.  The blower section can be reposi-
tioned as shown in Figure  2 for horizontal applications.

SAFETY CONSIDERATIONS

Installer should pay particular attention to the words:

NOTE

CAUTION

, and 

WARNING

. Notes are intended

to clarify or make the installation easier. Cautions are
given to prevent equipment damage. Warnings are
given to alert installer that personal injury and/or equip-
ment damage may result if installation procedure is not
handled properly.

RENEWAL PARTS

Refer to parts Manual for complete listing of replace-
ment parts on this equipment.  The forms referenced in
this instruction may be ordered from:

Standard Register
2101 West Tecumseh Road
Norman, Oklahoma 73069
Toll Free TEL: 877-318-7920
Toll Free FAX: 877-379-7920

This instruction covers the installation and operation of 
evaporator blower units.  For information on the opera-
tion of the matching condensing unit, refer to Form 
035-18506-001. 

AGENCY APPROVALS

Design certified by UL as follows:

 1. For use as a cooling coil/air handler only.

 2. For indoor installation only.

INSPECTION

As soon as a unit is received, it should be inspected for
possible damage during transit.  If damage is evident,
the extent of damage should be noted on the carrier's
freight bill.  A separate request for inspection by the
carrier's agent should be made in writing.

Improper installation may create a condition
where the operation of the product could cause
personal injury or property damage.

Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. refer to this manual for
assistance or additional information, consult a
qualified installer, service agency.

This product must be installed in strict compli-
ance with the enclosed installation instructions
and any applicable local, state, and national
codes including but not limited to, building,
electrical and mechanical codes.

Summary of Contents for LA120

Page 1: ...IONS 4 AGENCY APPROVALS 4 INSPECTION 4 INSTALLATION 6 MAINTENANCE 16 NOTES CAUTIONS AND WARNINGS Installer should pay particular attention to the words NOTE CAUTION and WARNING Notes are intended to c...

Page 2: ...ION 8 4 SUPPLY AIR PLENUM ACCESSORY 9 5 BASE ACCESSORY VERTICAL ONLY 9 6 RECOMMENDED DRAIN PIPING 10 7 RETURN AIR GRILLE ACCESSORY VERTICAL 10 Fig Pg 8 FIELD WIRING DIAGRAMS FOR POWER SUPPLY 12 9 FIEL...

Page 3: ...tandard Efficiency 2 Pipe B R 22 Standard Efficiency 4 Pipe 120 Nominal Cooling Capacity MBH 090 7 1 2 Ton 120 10 Ton 150 12 1 2 Ton 180 15 Ton 240 20 Ton C Heat Type C Cooling Only 00 Nominal Heating...

Page 4: ...on this equipment The forms referenced in this instruction may be ordered from Standard Register 2101 West Tecumseh Road Norman Oklahoma 73069 Toll Free TEL 877 318 7920 Toll Free FAX 877 379 7920 Thi...

Page 5: ...provided in the filter rack Qty Size in 6 20 X 20 X 1 Face Area Sq Ft 16 7 Operating Charge Refrigerant 22 Lbs Oz 5 8 Weight Lbs Shipping 439 Operating 399 Accessory Weights Lbs Electric Heaters 10 K...

Page 6: ...e suspended from above as shown in Figure 1 Refer to Form 035 16622 001 for more information on the installation of the suspension accessory and for the individual load on each hanger rod A field adde...

Page 7: ...illips machine bolts that hold the coil and blower sections together A bolt is located near each corner 3 Move the blower section to the proper location 4 Attach the blower section to the coil section...

Page 8: ...CCESS OPENING FOR POWER SUPPLY WIRING 1 2 WIRING HARNESS LOCATION This opening in the bottom of the heater control box is used for the wiring harness that connects the heater accessory to the basic un...

Page 9: ...n and a sealing material such as permagum should be packed around refrigerant lines where they penetrate a wall to reduce vibration and to retain some flexibility Support all refrigerant lines at mini...

Page 10: ...ith these codes Route the power wires into the unit through one of the 7 8 knockouts in the panel with the supply air opening and connect them to the terminals on blower motor contactor 10M Route the...

Page 11: ...t is made by moving the blower motor mount ing plate Refer to Figure 7 Turning the adjustment bolt B moves the motor mounting plate up or down Note Never loosen the tow nuts C Two hex nuts A have to b...

Page 12: ...orator coil may vary greatly measuring the pressure drop across a wet coil under field conditions would be inaccurate To assure a dry coil the refrigerant system should be de activated while the test...

Page 13: ...Motor Blower HP Blower RPM Adjustable Motor Pulley Fixed Blower Pulley Belt Pitch Dia Inches Bore Inches Pitch Dia Inches Bore Inches Designation Pitch Lg Inches LA120 2 549 716 3 1 4 1 7 8 9 5 1 A55...

Page 14: ...ing air stream upstream of any heating device Units with steam or hot water coils are the only exception LA120 3000 3500 4000 4500 5000 5500 6000 6500 7000 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 1 1...

Page 15: ...1 9 1 0 2 1 8 2 5 8 K N O C K O U T F O R 1 5 8 O D S U C T I O N C O N N 3 2 3 8 1 8 7 8 6 5 1 2 5 7 8 B L O W E R S E C T I O N 7 1 4 1 6 1 2 7 8 1 9 3 8 2 1 7 8 6 0 3 4 B L O W E R M O T O R A N D...

Page 16: ...LUBRICATION The bearings for the blower shaft and the blower motors are permanently lubricated and should not require additional lubricant BELTS Maintain belt tension to extend belt life Replace when...

Reviews: