![Unitary products group DAPM024 Installation Manual Download Page 8](http://html1.mh-extra.com/html/unitary-products-group/dapm024/dapm024_installation-manual_4004904008.webp)
176169-BIM-A-0206
8
Unitary Products Group
*. KW listed is for 240 volts, use this table for 208 or 230 volts.
**. KW listed is for 480 volts, use this table for 460 volts.
TABLE 5: ELECTRICAL DATA (COOLING/ELECTRIC HEAT) DPM024, 030, 036, 042, 048 AND 060
MODEL
DPM
POWER
SUPPLY
COMPRES
SOR
OUTDOOR.
FAN
MOTOR,
FLA
SUPPLY
AIR BLOWER
MOTOR, FLA
ELECTRIC HEAT ACCESSORY
MIN.
CIRCUIT
AMPACITY
(AMPS)
MAX.
FUSE
SIZE
1
(AMPS)
1. Dual element, time delay type.
MAX.
HACR
2
BREAKER
SIZE
(AMPS)
2. Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused.
RLA
LRA
MODEL
NO.
STAGE
KW
TOTAL
AMPS
024
208/230-1-60 10.0
55.0
1.2
4.3
2NH04500506
1
3.8/5.0 *
18.1/20.8
28.2/31.4
30/35
30/35
2NH04500706
2
5.6/7.5 *
27.1/31.3
39.0/44.4
40/45
40/45
2NH04501006
2
7.5/10.0 * 36.1/41.7
50.4/57.5
60/60
60/60
030
208/230-1-60 11.2
68.0
1.2
4.3
2NH04500506
1
3.8/5.0 *
18.3/20.8
28.2/31.4
30/35
30/35
2NH04500706
2
5.6/7.5 *
26.9/31.3
39.0/44.4
40/45
40/45
2NH04501006
2
7.5/10.0 * 36.1/41.7
50.4/57.5
60/60
60/60
2NH04501506
2
11.3/15.0 * 54.2/62.5
73.3/83.5
80/90
80/90
036
208/230-1-60 15.4
88.0
1.2
4.3
2NH04500506
1
3.8/5.0 *
18.1/20.8
28.2/31.4
35/40
35/40
2NH04500706
2
5.6/7.5 *
27.1/31.3
39.0/44.4
40/45
40/45
2NH04501006
2
7.5/10.0 * 36.1/41.7
50.4/57.5
60/60
60/60
2NH04501506
2
11.3/15.0 * 54.2/62.5
73.3/83.5
80/90
80/90
042
208/230-1-60 21.1 115.0
1.2
6.8
2NH04500506
1
3.8/5.0 *
18.3/20.8
34.4/34.5
45/45
45/45
2NH04500706
2
5.6/7.5 *
26.9/31.3
42.2/47.6
50/50
50/50
2NH04501006
2
7.5/10.0 * 36.1/41.7
53.6/60.6
60/70
60/70
2NH04501506
2
11.3/15.0 * 54.3/62.5
76.4/86.6
80/90
80/90
048
208/230-1-60 20.5 115.0
1.2
6.8
2NH04501006
2
7.5/10.0 * 36.1/41.7
53.6/60.6
60/70
60/70
2NH04501506
2
11.3/15.0 * 54.2/62.5
76.4/86.6
80/90
80/90
2NH04502006
2
15.0/20.0 * 72.2/83.3 98.6/112.7 100/125 100/125
2NH04502506
2
18.8/25.0 * 90.3/104.2 121.5/138.7 125/150 125/150
060
208/230-1-60 25.0 169.0
1.2
9.1
2NH04501006
2
7.5/10.0 * 36.1/41.7
56.4/63.5
60/70
60/70
2NH04501506
2
11.3/15.0 * 54.2/62.5
79.3/89.5
80/90
80/90
2NH04502006
2
15.0/20.0 * 72.2/83.3 101.5/115.5 110/125 110/125
2NH04502506
2
18.8/25.0 * 90.3/104.2 124.4/141.6 125/150 125/150
036
208/230-3-60 10.2
77.0
1.2
4.3
2NH04501025
1
7.5/10.0 *
20.8/24.1
31.4/35.4
35/40
35/40
2NH04501525
1
11.3/15.0 * 31.4/36.1
44.6/50.5
45/60
45/60
042
208/230-3-60 13.4
89.0
1.2
6.8
2NH04501025
1
7.5/10.0 * 20.8/24.1
34.5/38.6
35/40
35/40
2NH04501525
1
11.3/15.0 * 31.4/36.1
47.7/53.6
50/60
50/60
048
208/230-3-60 14.1
90.0
1.2
6.8
2NH04501025
1
7.5/10.0 * 20.8/24.1
34.5/38.6
35/40
35/40
2NH04501525
1
11.3/15.0 * 31.3/36.1
47.7/53.6
50/60
50/60
2NH04502025
2
15.0/20.0 * 41.7/48.1
60.5/68.6
70/70
70/70
2NH04502525
2
18.8/25.0 * 52.1/60.1
73.7/83.7
80/90
80/90
060
208/230-3-60 17.3 123.0
1.2
9.1
2NH04501025
1
7.5/10.0 * 20.8/24.1
37.4/41.4
45/45
45/45
2NH04501525
1
11.3/15.0 * 31.3/36.1
50.6/56.5
60/60
60/60
2NH04502025
2
15.0/20.0 * 41.7/48.1
63.4/71.5
70/80
70/80
2NH04502525
2
18.8/25.0 * 52.1/60.1
76.6/86.6
80/90
80/90
036
460-3-60
5.1
39.0
0.75
4.3
2NH04501046
1
10.0 **
12
17.7
20
20
2NH04501546
1
15.0 **
18
25.2
30
30
042
460-3-60
6.4
45.0
0.75
6.8
2NH04501046
1
10.0 **
12.0
19.3
20
20
2NH04501546
1
15.0 **
18.0
26.8
30
30
048
460-3-60
7.1
45.0
0.75
6.8
2NH04501046
1
10.0 **
12.0
19.3
20
20
2NH04501546
1
15.0 **
18.0
26.8
30
30
2NH04502046
2
20.0 **
24.1
34.3
35
35
2NH04502546
2
25.0 **
30.1
41.8
45
45
060
460-3-60
7.4
49.5
0.75
9.1
2NH04501046
1
10.0 **
12.0
20.7
25
25
2NH04501546
1
15.0 **
18.0
28.2
30
30
2NH04502046
2
20.0 **
24.1
35.8
40
40
2NH04502546
2
25.0 **
30.1
43.2
45
45
Nominal
Voltage
Voltage
KW Capacity
Multiplier
240
208
0.75
230
0.92
480
460
0.92