degrees Fahrenheit, press and hold the 

MIN/MAX

 button for 3 seconds in normal mode. 

 

3.5

 

Backlight

 

Operation

 

To temporarily turn on the back light for five seconds, press the 

any

 button on the indoor sensor. 

 

4

   

Adjustment

 

or

 

Calibration

 

Note: 

The measured humidity range is between 10 and 99%. Humidity cannot be accurately 

measured outside of this range. Thus, the humidity cannot be calibrated below 10% or above 99%. 
 
The purpose of calibration is to fine tune or correct for any sensor error associated with the devices 
margin of error. The measurement can be adjusted from the console to calibrate to a known source. 
 
Calibration is only useful if you have a known calibrated source you can compare it against, and is 
optional. This section discusses practices, procedures and sources for sensor calibration to reduce 
manufacturing and degradation errors. Do not compare your readings obtained from sources such as 
the internet, radio, television or newspapers. They are in a different location and typically update once 
per hour. 
 
The purpose of your weather station is to measure conditions of your surroundings, which vary 
significantly from location to location. 

4.1

 

Humidity

 

Calibration

 

To enter the humidity calibration mode, press and hold the 

SET and MIN/MAX

 buttons at the same 

time for 3 seconds and the humidity value will begin flashing. Press the 

CH/+

 button to increase the 

humidity and the 

MIN/MAX/-

 button to decrease the humidity reading in 1% increments. To rapidly 

increase (or decrease) the humidity reading, press and hold the 

CH/+

 or 

MIN/MAX/-

 button. 

 
To return the humidity to the actual or uncalibrated measurement, press the 

SET

 button. 

will be displayed when the humidity calibrated measurement. 

 
Once the displayed humidity equals the calibrated source, press and hold the 

SET 

button for three 

seconds, or wait 15 seconds for timeout, and the humidity value will stop flashing. 

4.2

 

Temperature

 

Calibration

 

To enter the temperature calibration mode, press and hold the 

SET and CH/+ 

buttons for 3 seconds 

and the temperature value will begin flashing. Press the 

CH/+

 button to increase the temperature and 

the 

MIN/MAX/-

 button to decrease the temperature reading in 0.1° increments. To rapidly increase 

(or decrease) the temperature reading, press and hold the 

CH/+

 or 

MIN/MAX/-

 button. 

 
To return the temperature to the actual or uncalibrated measurement, press the 

SET

 button. 

will be displayed when the humidity calibrated measurement. 

 
Once the displayed temperature equals the calibrated source, press and hold the 

SET 

button for three 

seconds, or wait 15 seconds for timeout, and the temperature value will stop flashing. 
 

Discussion

:

 

Temperature errors can occur when a sensor is placed too close to a heat source (such 

as a building structure, the ground or trees). 

Summary of Contents for FT012TH

Page 1: ...battery door on the back of the display 1 Insert two AAA alkaline or lithium avoid rechargeable batteries in the back of the indoor sensor Figure 1 2 Insert two AAA batteries After inserting the batte...

Page 2: ...Max Clears daily mode 8 Low power indicator 9 Humidity Calibrated Icon when the calibration is displayed 10 Humidity Comfort Colorful Icon 11 Relative Humidity 12 Channel 1 2 3 4 5 6 7 8 indictor 13 M...

Page 3: ...1 Outdoor sensor default is Channel 1 The FT012TH supports up to eight transmitters 3 2 Min Max Mode The Min Max mode displays the minimum and maximum temperature and humidity since reset of the unit...

Page 4: ...me time for 3 seconds and the humidity value will begin flashing Press the CH button to increase the humidity and the MIN MAX button to decrease the humidity reading in 1 increments To rapidly increas...

Page 5: ...humidity match closely with the console and sensor array in the same location about 5 to 10 apart The sensors should be within 10 the accuracy is 5 Allow about 30 minutes for both sensors to stabiliz...

Page 6: ...ication is intermittent try turning off these other devices for troubleshooting purposes You may need to relocate the transmitters or receivers to avoid intermittent communication 3 Line of Sight Rati...

Page 7: ...indoor thermometer hygrometer sensor Backlight often light may reduce the battery life 6 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device...

Page 8: ...s working and the transmitter light is flashing once per 48 seconds Install a fresh set of batteries in the remote thermo hygrometer For cold weather environments install lithium batteries Make sure t...

Page 9: ...Problem Solution Display contrast is weak Replace console batteries with a fresh set of batteries...

Reviews: