Step 10: Save setup
In “Alarms” menu, press “Confirm” button to save the parameters.
Press “Cancel” button or
[
ESC
]
key to abort.
Alarm relay output setup
Step 1:
In “Alarms” menu, use
[
↑
][
↓
]
keys to select one alarm output.
Step 2: Select delay time
The delay time is when the alarm is disappeared, the alarm output will continue output time.
The delay time options are: 5 Seconds, 10 Seconds, 30 Seconds, 1 Minute, 2 Minutes, 5 Minutes,
10 Minutes and Manual Stop. If you select “Manual’ option, the alarm output will not stop until
you press “Clear Alarm” button in “Utilities” menu. So the actual alarm output time is made up of
alarm input time and this delay time.
Step 3: Enter into alarm out schedule
You can set the schedule to make alarm output into effective. Move “Active Frame” to
“Schedule” button on right side of “Alarm Out Time” item, press
[
ENTER
]
key to enter into the
corresponding schedule menu: Shown as fig 5.25
Fig 5.25 Alarm out schedule
Step 4: Setup alarm out schedule
Like other schedule setup, you can set 4 time periods for one day and 7 days for one week.