Warning
II
Warning
II
Warning
●
Prepare a safety circuit outside the F325 so that the entire system functions safely if the
F325 fails or malfunctions.
●
Be sure to contact our sales representative before use if the F325 will be used as follows:
- if the indicator is used in an environment not described in the operation manual;
- if the indicator is used in a way that causes substantial effects on medical devices,
transportation equipment, entertainment devices, safety devices, etc.
●
Do not disassemble, repair, or alter the F325. Fire or electric shock may occur.
●
Do not install into the following environments:
- Locations with corrosive gas or combustible gas;
- Locations over which water, oil, or chemical splash
●
Do not connect commercial power supply directly to a signal I/O terminal.
●
Be sure to perform class D grounding when installing the main unit
●
The AC cable included is for use in Japan and the rating is AC125V, 7A. Prepare a separate
AC cable if the indicator is used at a voltage higher than the rating or is used overseas.
●
Be sure to check that the power is off before the following actions:
- Removal and installation of optional connectors and so forth;
- Wiring and connection of cables to a signal I/O terminal;
- Connection to protective grounding terminals.
●
Be sure to check signal names and pin assignment numbers and to wire cables properly
before connecting to a signal I/O terminal.
●
Make sure to attach the terminal block cover included after wiring power supply. Electric
shock may occur.
●
Be sure to check wiring and so on carefully before turning power on.
●
Use power supply voltage and load within the specified range and rating.
●
Do not damage power cords. Fire or electric shock may occur.
●
Do not touch a signal I/O terminal while the power is on. This may cause electric shock and
malfunction.
●
Electric shock may occur inside when the cover of the main unit is opened. Internal
capacitors are charged even if power supply is cut off. Contact us for inspection and repair of
internal parts.
●
Turn power off and unplug power cable immediately if smoke, abnormal smell, or abnormal
noise is detected.
Events that may cause death or severe injury
to personnel in the event of misuse.
Design warning
Installation warning
Wiring warning
Startup/maintenance warning