33
Troubleshooting Guidelines
PROBLEM
POSSIBLE CAUSE
POSSIBLE REMEDY
UV Bulb is not turning on
a. Main disconnect off
b. Main breaker tripped
c. Rear guard open
d. Internal breakers tripped
e. E-Stop is pressed
f. Solid State power supply
g. Room is too cold
a. Turn to on
b. Reset
c. Close guard, check switch
d. Check circuit breakers
e. Reset E-Stop
f. Consult Solid State power
supply troubleshooting
g. Heat room
Main drive motor will not start
a. No power to the
unit
b. Main disconnect off
c.
Safety guard(s) open
d. E-Stop is pressed
a. Check incoming power panel
b. Turn to on
c.
Close guard(s), check switch
d. Reset E-Stop
Main motor is on but the Belt is
not running
a. Loose Belt
a. Check Belt
Coating getting on the backside
of the sheet
a. Form to Impression roller
pressure is too tight
a. Decrease the Form to
Impression roller pressure
Coating is not even on the sheet
a. Form to Impression roller is
not even
b. Form to Metering roller nip
pressure is too light
c. Form to Metering roller nip
pressure is not even
d. Not enough coating in the
nip
a. Adjust Form to Impression
roller so that it is even
b. Increase the Form to
Metering roller pressure
c. Make sure pressure is even
d. Add more coating to the nip
by pressing the coating fill
button
Coating is not curing
a. Old UV Bulb
b. Conveyor running too fast
c. Old coating
a. Replace UV Bulb
b. Slow down conveyor
c. Check coating receive date,
purchase new coating