EV CHECK
32
8-3-2.Proximity Pilot (PP) State (Cable Simulation)
•
With the PP State rotary switch various current capabilities of the charging cable can be simulated when the test
adapter is connected to the charging station.
• Current capabilities are simulated with different resistances connected between PP and PE conductors.
• Correlation between resistance and current capability of the charging cable is shown in Table below:
Correlation between resistance and current capability of the charging cable
Marking of cable current capability
Resistance between PP and PE
No cable
Open (
∞
)
13A
1.5k
Ω
20A
680
Ω
32A
220
Ω
63A
100
Ω
8-3-3.Control Pilot (CP) State (Vehicle Simulation)
•
With the CP State rotary switch selector various vehicle states can be simulated, when the test adapter is
connected to the charging station.
• Vehicle states are simulated with different resistances connected between CP and PE conductors.
• Correlation between resistance and vehicle is shown in Table below:
Correlation between resistance, vehicle state and CP voltage signal
Marking of
Vehicle State
Vehicle State
Resistance
between CP and PE
Voltage at CP
terminal (1kHz)
A
Electric vehicle (EV) not connected
Open (
∞
)
±12V
B
Electric vehicle (EV) connected, not
ready to charge
2.74k
Ω
+9V/-12V
C
Electric vehicle (EV) connected,
ventilation not required,ready to charge
882
Ω
+6V/-12V
D
Electric vehicle (EV) connected,
ventilation required,ready to charge
246
Ω
+3V/-12V
8-3-4.CP Signal Output Terminals
•
CP output terminals are connected to CP and PE conductors of the tested charging station via the test cable, the
green socket is connected to PE.
• This output is intended for connection of an oscilloscope to check the waveform and amplitude of the CP signal.
• Control Pilot function uses Pulse Width Modulation (PWM).
•
The purpose of the Control Pilot function is communication between a vehicle and charging station, the duty cycle
of the PWM signal defines the possible available charging current.
•
For details of communication protocol please refer to IEC/EN 6
1
851-1& IEC/HD 60364-7-722 and the documentation of
the manufacturer of the charging station.
Summary of Contents for EV CHECK
Page 1: ...EV CHECK Test delle colonnine di ricarica per veicoli elettrici Manuale Utente...
Page 36: ...Lisez ce manuel avant d allumer l unit Informations importantes sur la s curit l int rieur...
Page 54: ...EV CHECK Tests der Lades ulen f r Elektrofahrzeuge Benutzerhandbuch...
Page 72: ...Rev 200817...