PART I: SPECIFICATIONS
6
Burner model identification
Burners are identified by burner type and model. Burner model identification is described as follows.
Technical Specifications
(**) The distance between the measurement surface and the burner body is 1 meter (UNI EN ISO 3744)
Type
HR2050
Model
MG. MD. S.
*.
A
.
8.
80.
ES.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(8)
1 BURNER TYPE
HR2050, HR2060, HR2080
2 FUEL
MG - Natural gas-Light oil
3 OPERATION (Available versions)
MD - Fully modulating
4 BLAST TUBE
S - Standard
5 DESTINATION COUNTRY
* - see data plate
6 BURNER VERSION
A - Standard
Y - Special
7 EQUIPMENT
1 = 2 gas gas proving system
8 = 2 gas gas proving maximum gas pressure switch
8 GAS CONNECTION
80 = DN80
100 = DN100
125 = DN125
8 MICRO-PROCESSOR CONTROL
ES = with no O
2
trim control, with no VSD control
EO = with O
2
trim control, with no VSD control
EI = with no O
2
trim control, with VSD control
EK = with O
2
trim control, with VSD control
HR2050
HR2060
HR2080
Output
min. - max. kW
2500 - 15200
2500 - 16000
2500 - 19000
Fuel
MG - Natural gas-Light oil
Category
(see next paragraph)
Gas rate min.-max.
min.- max. (Stm
3
/h)
265 - 1608
265 - 1693
265 - 2011
Pressure
mbar
(see Note 2)
Light oil rate
min.-max. kg/h
211 - 1282
211 - 1349
211 - 1602
Oil viscosity
cSt @ 40 °C
2 - 7,4
Oil density
kg/m
3
840
Oil train inlet pressure
bar
2 max
Power supply
400V 3N ~ 50Hz
Total power consumption
kW
4
1,5
51
61
Pump motor
kW
4
5,5
5,5
Fan motor power consumption
kW
37
45
55
Protection
IP40
Operation
MD - Fully modulating
Gas train 80
ØValves / Connection
3” /
DN
80
Gas train 100
ØValves / Connection
4” /
DN
100
Gas train 125
ØValves / Connection
5” /
DN
125
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service
Continuous
Noise level (sound power level)(**)
93
Note1:
All gas flow rates are referred to Stm
3
/h (1.013 mbar absolute pressure, 15° C temperature) and are valid for G20 gas
(net calorific value H
i
= 34.02 MJ / Stm
3
);
Note2:
Maximum gas pressure = 500mbar (with
Siemens VGD or Dungs MultiBloc MBE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80 %