73
Start Remote Mode and Change Transfer Speed:
Through the Menu system, select
3:SYSTEM OPTION
/
5:PC
CONTROL
by rotating the
VFO
and
pressing
E
. To start Remote mode,
choose from the transfer speed list
except for
5:OFF
.
A unique feature of the UBC3300XLT is that all the front panel
keys as well as the
VFO
on the radio remain operational in
Remote mode.
PC Control Parameter
For your information:
Transfer speed : 2400/4800/9600/19200 bps (adjustable)
Start/Stop
: 1 bit, 1 bit
Data Length
: 8 bit
Parity bit
: None
Code
: ASCII code
Flow Control
: None
Return Code
: Carriage Return only
Clone Mode
You will need to purchase a Gender Changer and a null
modem adapter. Gender Changer cables are available as
male to male or male to female. Even if the Gender Changer
you buy already has the male to male connectors, you will still
have to have the null modem adapter. On the next page you
will see the pin connections that are internal to a standard
device. (These items are available at your local electronics
stores.)
SPEED
3:9600 bps
4:19200 bps
5:OFF