Manual – 3000 NRL Family
Unidata Manual - 3000 NRL Family - 17 09 2018.docx
Page 18
3016A – Product Options
Model Number
Description
3016A-000
Neon Remote Logger - Ethernet / 16 Analog Channels / Touch Screen Display
3016A-00G
Neon Remote Logger – Globalstar / 16 Analog Channels / Touch Screen Display
3016A-00I
Neon Remote Logger - Inmarsat / 16 Analog Channels / Touch Screen Display
3016A-00R
Neon Remote Logger – Iridium SBD / 16 Analog Channels / Touch Screen Display
3016A-0L0
Neon Remote Logger – Ethernet and LoRa / 16 Analog Channels / Touch Screen Display
3016A-0LG
Neon Remote Logger - Globalstar and LoRa / 16 Analog Channels / Touch Screen Display
3016A-0LI
Neon Remote Logger - Inmarsat and LoRa / 16 Analog Channels / Touch Screen Display
3016A-0LR
Neon Remote Logger - Iridium SBD and LoRa / 16 Analog Channels / Touch Screen Display
3016A-C00
Neon Remote Logger - Ethernet and 3G/4G / 16 Analog Channels / Touch Screen Display
3016A-C0I
Neon Remote Logger - Inmarsat and 3G/4G / 16 Analog Channels / Touch Screen Display
3016A-CL0
Neon Remote Logger – Ethernet, 3G/4G and LoRa / 16 Analog Channels / Touch Screen Display
4.2
3008A Neon Remote Logger – 8 Analogue Channels
The 3008 Neon Remote Logger NRL is self-contained
data logger/RTU with 8 high resolution analogue
channels in a compact case which connects to sensors
in the field, collects readings from those sensors and
transmits the collected data to a central Neon server, or
it can be set up to operate as a stand-alone data
logger/RTU. The model number suffix indicates data
transmission via a cellular 2G/3G network or via a
cellular 4G/LTE network, satellite or Wi-Fi network.
4.2.1 3008
Specifications
Physical specifications
Material:
Powder Coated Aluminium Enclosure
Size:
282mm x 122mm x 40mm (LxWxH)
Weight:
650 grams
Operating Temperature:
-20°C to 60°C. Not affected by humidity
Antennae:
Model dependent,
external stub/whip/satellite antenna
Electrical Specifications
External Power:
9 to 30V DC (provision for dual power inputs)
Current Draw:
<800
μ
A Standby, Max 500mA Active
RTC Backup Battery:
3.6V Li Coin Cell (5 year life)
Instrument Power /
Reference Voltage:
12V regulated, 200mA fused and 5V regulated, 100mA fused
Analog Channels:
8 Single ended (max) or 4 Differential (max),