Manual – 3000 NRL Family
Unidata Manual - 3000 NRL Family - 17 09 2018.docx
Page 28
Unidata HSIO:
High speed serial interface
Counters:
4,
2 x 16 bit, DC to 3KHz potential free contacts or
0 to 5V DC digital input (C0,C2),
2 x 16 bit, DC to 300Hz potential free contacts or
0 to 5V DC digital input (C1,C3)
Digital Outputs:
1 Open Drain FET, 30V DC, 250mA max
Configuration Port:
USB serial port
Operating Frequencies:
LoRa AU915, US915, EU868, AS923
Scan Rate:
Programmable from 1 sec to 5 min
Log Rate:
Programmable from 1 sec to 24 hours
Accelerometer:
Senses changes in logger orientation
LCD Display
Optional, 320 x 240, Colour, Resistive Touch Panel
Keypad
Optional, 5 button membrane keypad
3004B-ML – Product Options
Model Number
Description
3004B-ML00
NRL LoRa No Batteries (no LCD)
3004B-MLB0
NRL LoRa with Lithium Battery (no LCD)
3004B-ML0L
NRL LoRa No Batteries with LCD
3004B-MLBL
NRL LoRa with Lithium Battery with LCD
4.9
3001B-MC/L/I/H Borehole Neon Remote Logger Cellular, LoRa, Iridium SBD or
Microsatellite
The 3001M Borehole Logger is a Neon Remote
Logger in the M range that is designed for use in
boreholes of 100mm internal diameter and above.
It can be configured to use ether Cellular, LoRa,
Iridium or Microsatellite networks as its method of
sending sensor data from the field to the Neon
Server.
4.9.1 3001B-MC/L/I/H
Specifications
Physical specifications
Material:
Polycarbonate
Size:
190mm x 80mm x 55mm (LxWxH)
Weight:
300 grams
Operating Temperature:
-20°C to 60°C. Not affected by humidity
Antennae:
External Low Profile antenna
Electrical Specifications
External Power:
9 to 30V DC