Manual – Starflow QSD Model 6527B and 6537A
Unidata Manual - 6527B and 6537A Starflow QSD User Manual 17 01 2020.docx
Page 4
Environmental
Operating
0°C to 60°C (water temperature)
Storage
-20°C to 60°C
Humidity
up to 100 % RH
Physical
Dimensions
Approximately L 135 mm, W 55 mm, H 22 mm
Material
Epoxy-sealed body, stainless steel mount
Weight
1kg with 15m of Cable
Cable
15 metre
Cable options
User-specified, up to 50 metres
Instrument Wiring Table
Variants for Wiring are detailed below
Brown Wire Variant
Starflow QSD / Wire Colour
Function / Signal Name
White
SDI-12
Brown
Power
Green
Ground
Yellow
A- (Modbus)
Pink
B+ (Modbus)
Grey
One-Wire
*
Red Wire Variant
Starflow QSD / Wire Colour
Function / Signal Name
White
SDI-12
Red
Power
Yellow
Ground
Blue
A- (Modbus)
Orange
B+ (Modbus)
Grey
One-Wire
*
* Use with Unidata 6515A QSD Barometric Reference Module
When Unidata 6515A QSD Barometric Reference module is connected, the instrument will
automatically handle the barometric correction and will report actual water level instead of water head
plus atmospheric pressure.
If your data logger has a barometric sensor, the data logger program must perform the barometric
correction OR the user can perform a post processing method to correct for barometric changes by
using barometric pressure data from a trusted source such as a weather department or another
barometer close by.
The 6515A QSD Barometer Reference module should be:
a) Mounted in an enclosure near to the data logger in a position protected from the elements.
b) The enclosure should be vented to allow the barometer sensor to be exposed to atmospheric
pressure variations.