CAUTION

     

 

 
 

    

Read this manual before operating PowerSpin C8624 centrifuge 

 
Introduction: 
 

UNICO

®

 has been providing quality laboratory equipment for the medical labs for 12 

years. We are constantly working to improve our products with the latest technological 
innovations.  UNICO

®

 PowerSpin

 C8624 24 place centrifuge is released to meet the 

needs and offer safety features needed in the fast growing medical and health care 
industries. 

 
Description/ Intended Use

 

The UNICO

® 

 PowerSpin

 C8624 24 place centrifuges with digital variable speed control 

and electronic timer are specially designed to run for years of demanding laboratory work 
in clinical labs, physician’s offices as well as in any chemical, industrial or biological labs 
where separation for blood or other materials is desirable. 

 

Features: 
 

 

 

Push button keypad controls. 

 

24 place angled rotor for use with standard 3 to 15 ml tubes (glass or plastic).

 

(An optional adapter is required for tubes less than 10 ml or 100mm length) 

 

 

Digital speed control with speed range from 1,000rpm to 3,400 rpm.

 

 

Automatic and speed / RCF digital display simultaneously. 

 

 

Electronic 60 minutes timer with beeping signal at end of run.

 

 

Automatic time and speed reset to the last time speed and time setting for repeated job.

 

 

Memorized time and speed settings: The centrifuge will memorize the last time and 
speed settings when the unit is turned off. It will resume the previous time and speed 
settings when the unit is turned on.

 

 

Maintenance free brushless AC motor 

 

Safety: Zero RPM lid latch protection - The centrifuge lid cannot be opened until the 
unit stops spinning

It will not run unless the lid is properly closed.

 

 

Suction cup rubber feet for stable bench top operation 

 

Power switch with indicator light tells when unit is powered on.

 

 

Power on/off switch located on back of unit.

 

 

Construction: 

 

The enclosure of the PowerSpin C8624 24 place centrifuges is made of high impact 
plastic. The internal rotor chamber is made of stainless steel. A safety device is installed to 
prevent the lid from opening while the centrifuge is running. The motor is mounted on 
rubber mounts to provide quiet running and less vibration.  The Stainless Steel rotor 
chamber can be easily cleaned and disinfected. 

 
Accessories: 

 

Each Power Spin C8624 centrifuge comes equipped with angled rotor with 24-place tube 
shields already installed. 

 

Summary of Contents for PowerSpin C8624

Page 1: ...PowerSpin C8624 24 Place Centrifuge OPERATION MANUAL 182 Ridge Road Suite E Dayton NJ 08810 USA 800 588 9776 Fax 732 274 1151 Web www unicosci com...

Page 2: ...tal display simultaneously Electronic 60 minutes timer with beeping signal at end of run Automatic time and speed reset to the last time speed and time setting for repeated job Memorized time and spee...

Page 3: ...shion foam in the rotor chamber Do not operate the centrifuge before the foam is removed 1 Take the centrifuge from the Styrofoam and place it on a sturdy flat surface Do not turn on the centrifuge 2...

Page 4: ...conds To increase time setting press and hold up arrow otherwise down arrow button Speed Setting and Speed Setting Change Speed setting Use the up or down arrow to preset the running speed The speed r...

Page 5: ...total to date number of cycles will be displayed Note Cycles of usage is not total spinning time It represents the total times the centrifuge has spun Operation 1 Plug the centrifuge into a power sou...

Page 6: ...is not necessary A surface cleaner such as Formula 409 can be used to clean the outside of the instrument The rotor chamber and cover can be disinfected with a mild solution of bleach or other disinfe...

Page 7: ...switch in the back of unit is in the on position e Check that the power indicator light with the switch is lit A failure of the power light to illuminate could indicate a need for a new fuse when the...

Page 8: ...which is 250V 4A e Put the snap in fuse holder back 5 Intermittent motor operation or no operation Contact your representative for possible motor replacement Specifications Speed 1 000 3 400 RPM Spee...

Page 9: ...ed distributor or dealer within five 5 days after the occurrence of said defect No other warranty of any kind is made expresses or implied The warranty described above shall be the sole and exclusive...

Page 10: ...o response no response sound 1 Loose connection or connection reversed 2 Touch panel defective 1 Exercise the connector J2 on main 2 Replace touch panel 6 Display show Running but motor is not running...

Page 11: ...4 Centrifuge Parts and Nomenclature Lid Rotor Emergency lid opening left side Control panel Start Stop Open buttons Digital Timer Speed Control Safety lock On off switch on back side Power indicator M...

Reviews: