33
Tec
hnical f
eatures and dimensions
LIST OF PARAMETERS
Parameter
Boiler operating temperature (°C)
78
0
Minimum boiler temperature for starting the pumps (°C)
55
1
Maximum boiler temperature for alarm (°C)
88
2
Start temperature for filling storage tank (°C).
55
3
End temperature for filling storage tank (°C).
65
4
Maximum temperature for storage tank (solar protection) (°C).
90
5
Thermostat control temperature tolerance band for heating (°C)
2
6
Temperature tolerance band for filling storage tank (°C)
8
7
Maximum temperature tolerance band for boiler body (°C)
4
8
Temperature tolerance band for operating solar panels (°C)
10
9
PROBE CONFIGURATION PARAMETER
30
Probe 0: at 0 if absent, or at 1 if present
1
Probe 2: at 0 if absent, or at 2 if present
2
Probe 3: at 0 if absent, or at 4 if present
4
Probe 4: at 0 if absent, or at 8 if present
8
Probe 5: at 0 if absent, or at 16 if present
16
Parameter to be used for configuring probes
31
FUNCTIONAL CONFIGURATION PARAMETER
31
Def. 1: = at 0 if storage tank absent or at -1 if storage tank present
1
Def. 2: = at 0 if coil-type storage tank or at -2 if Combi or Puffer storage tank
2
Def. 3: = at 0 if solar panel absent or at -4 if solar panel present
0
Def. 4: = at 0 for optical ignition detection or at -8 for flue gas ignition detection
0
Parameter to be entered for functional settings
3
Language selection: 0 = Italian - 2 = English - 4 = French - 6 = Spanish
32
0
Shutdown delay time for wood function standby (seconds)
50
10
Number of burner start-up attempts
1
11
Duration of burner flame ignition cycle (minutes)
15
12
Time for detecting stability of burner flame (seconds)
30
13
Modulation of fuel and air in relation to boiler temperature
2
14
Time for cleaning burner (seconds)
20
15
Time for post-rotation of screw 2 (seconds)
22
21
Time for pre-igniting the burner (seconds)
30
16
Time for preloading fuel for ignition (seconds)
120
17
Burner pre-combustion time (minutes)
5
18
Time for running the screw motor ON (seconds)
26
19
Time for pausing the screw motor OFF (seconds)
22
20
Time for final cleaning of burners (seconds)
5
22
Speed of wood combustion
130
23
Fan speed with burner running
142
24
Fan speed in manual mode
128
25
Maximum operating temperature of the solar panels (°C)
160
26
Minimum flue gas temperature for detecting start-up of burner
60
27
ALLBIOMIX
Maximum wood smoke temperature with modulation of -15°C
215
28
Maximum gas flue temperature of burner with modulation of -15°C
180
29
Mod.
34
78
55
88
55
65
90
2
8
4
10
1
2
4
8
16
31
1
2
0
0
3
0
50
2
15
30
2
20
20
30
120
5
64
21
5
135
142
132
160
60
215
180
Mod.
45
Mod.
80
Summary of Contents for ALLBIOMIX
Page 1: ...ALLBIOMIX INSTRUCTIONS ON INSTALLATION USE AND MAINTENANCE ...
Page 4: ...4 This page has been intentionally left blank ...
Page 10: ...10 2 2 HYDRAULIC DIMENSIONS AND CONNECTIONS ...
Page 11: ...11 Technical features 2 3 INSTALLATION OF THE BOILER AND PELLET TANK ALLBIOMIX 34 ...
Page 12: ...12 ALLBIOMIX 45 ...
Page 13: ...13 Technical features ALLBIOMIX 80 ...
Page 24: ...24 4 5 6 7 ...
Page 47: ...47 ...